Numerical fitting of Extrapolated semisolid Magnetization transfer Reference (NEMR) signals: Improved detection of ischemic stroke
- 13 April 2023
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (2) , 722-736
Abstract
Purpose: To propose a novel Numerical fitting method of the Extrapolated semisolid Magnetization transfer Reference (NEMR) signal for quantifying the CEST effect.Theory and Methods: Modified two‐pool Bloch‐McConnell equations were used to numerically fit the magnetization transfer (MT) and direct water saturation (DS) signals at far off‐resonance frequencies, which was subsequently extrapolated into the frequency range of amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) pools. Then the subtraction of the fitted two‐pool z‐spectrum and the experimentally acquired z‐spectrum yielded APT# and NOE# signals mostly free of MT and DS contamination. Several strategies were used to accelerate the NEMR fitting. Furthermore, the proposed NEMR method was compared with the conventional extrapolated semisolid magnetization transfer reference (EMR) and magnetization transfer ratio asymmetry (MTRasym) methods in simulations and stroke patients.Results: The combination of RF downsampling, MT lineshape look‐up table, and conversion of MATLAB code to C code accelerated the NEMR fitting by over 2700‐fold. Monte‐Carlo simulations showed that NEMR had higher accuracy than EMR and eliminated the requirement of the steady‐state condition. In ischemic stroke patients, the NEMR maps at 1 μT removed hypointense artifacts seen on EMR and MTRasym images, and better depicted stroke lesions than EMR. For NEMR, NOE# yielded significantly (p < 0.05) stronger signal contrast between stroke and normal tissues than APT# at 1 μT.Conclusion: The proposed NEMR method is suitable for arbitrary saturation settings and can remove MT and DS contamination from the CEST signal for improved detection of ischemic stroke.Keywords
Funding Information
- National Natural Science Foundation of China (81971605, 82171907)
- National Natural Science Foundation of China
This publication has 59 references indexed in Scilit:
- MR imaging of the amide‐proton transfer effect and the pH‐insensitive nuclear overhauser effect at 9.4 TMagnetic Resonance in Medicine, 2012
- In vivo three‐dimensional whole‐brain pulsed steady‐state chemical exchange saturation transfer at 7 TMagnetic Resonance in Medicine, 2011
- Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectraJournal of Magnetic Resonance, 2011
- Optimizing pulsed‐chemical exchange saturation transfer imaging sequencesMagnetic Resonance in Medicine, 2011
- Saturation power dependence of amide proton transfer image contrasts in human brain tumors and strokes at 3 TMagnetic Resonance in Medicine, 2011
- Optimization of pulse train presaturation for CEST imaging in clinical scannersMagnetic Resonance in Medicine, 2011
- Differentiation between glioma and radiation necrosis using molecular magnetic resonance imaging of endogenous proteins and peptidesNature Medicine, 2010
- Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readoutMagnetic Resonance in Medicine, 2010
- Assessment of glycosaminoglycan concentration in vivo by chemical exchange-dependent saturation transfer (gagCEST)Proceedings of the National Academy of Sciences, 2008
- Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain ImagesNeuroImage, 2002