A comparison of the Pentax Airway Scope™ with the Airtraq™ in an infant manikin
Authors:
- 16 April 2012
- journal article
- research article
- Published by Wiley in Anaesthesia
- Vol. 67 (8) , 881-884
Abstract
Summary: We compared the Pentax Airway Scope TM with the Airtraq TM optical laryngoscope in an infant manikin. Twenty‐three anaesthetists randomly performed tracheal intubation: at rest, (a) with the Airway Scope and (b) with the Airtraq; and during chest compressions, (c) with the Airway Scope and (d) with the Airtraq. The success rate, modified Cormack and Lehane classification for glottic view, time taken to view the glottis, and time to place the tracheal tube were recorded. There was no difference in intubation success rate or quality of glottic view between the two devices. The median (IQR [range]) time taken to obtain a view of the glottis was 4.5 (3.7–6.4 [1.8–14.0]) s using the Airway Scope compared with 7.1 (5.5–9.6 [3.3–12.0]) s using the Airtraq (p = 0.001), and to successful placement of the tracheal tube was 8.3 (6.8–9.4 [3.7–20.7]) s using the Airway Scope compared with 11.2 (10.4–13.8 [4.9–23.7]) s using the Airtraq (p = 0.001). During chest compressions, the median (IQR [range]) time taken to view the glottis was 5.1 (4.0–7.2 [2.0–12.4]) s using the Airway Scope compared with 7.5 (5.0–13.2 [4.2–26.4]) s using the Airtraq (p = 0.006), and to successful placement of the tracheal tube was 9.5 (6.6–13.7 [4.5–16.2]) s using the Airway Scope compared with 11.7 (9.1–18.1 [6.2–37.4]) s using the Airtraq (p = 0.022). We conclude that both devices provided good quality views of the glottis and successful tracheal intubation in an infant manikin both at rest and during external chest compressions. Use of the Airway Scope resulted in a shorter time to view the glottis and perform successful tracheal intubation compared with the Airtraq.Keywords
This publication has 22 references indexed in Scilit:
- Evaluation of the Bullard, GlideScope, Viewmax, and Macintosh laryngoscopes using a cadaver model to simulate the difficult airwayJournal of Clinical Anesthesia, 2011
- Part 14: Pediatric Advanced Life SupportCirculation, 2010
- Part 15: Neonatal ResuscitationCirculation, 2010
- European Resuscitation Council Guidelines for Resuscitation 2010 Section 6. Paediatric life supportResuscitation, 2010
- Utility of the Pentax-AWS® without interruption of chest compression: Comparison of the Macintosh laryngoscope with the Pentax-AWS® in manikin modelResuscitation, 2010
- Pentax-AWS (Airway Scope) and Airtraq: big difference between two similar devicesJournal of Anesthesia, 2008
- The Pentax‐AWS ® rigid indirect video laryngoscope: clinical assessment of performance in 320 cases*Anaesthesia, 2008
- Tracheal intubation of morbidly obese patients: a randomized trial comparing performance of Macintosh and Airtraq™ laryngoscopesBritish Journal of Anaesthesia, 2008
- The Airtraq ® as a rescue airway device following failed direct laryngoscopy: a case seriesAnaesthesia, 2007