Broadband calibration of radio-frequency magnetic induction probes

Authors:

Abstract
We describe broadband calibration of a magnetic induction probe using a network analyzer. Our procedure uses a small driver coil and the scattering matrix associated with the coil-probe pair. This allows rapid, high-resolution measurements of the amplitude and phase of the probe’s response to oscillating magnetic fields. Our setup gives high accuracy between 100kHz and 100MHz and less accuracy outside this range. We present over 1800 sensitivity measurements between 30kHz and 1GHz . The ideal probe response is compared to calibrations done with two different driver coils. We discuss several hurdles in probe design and calibration, as well as several high-frequency effects.

This publication has 14 references indexed in Scilit: