Appraising Efficiency of OpSite as Coolant in Drilling of Bone
Authors:
Preprint
- 15 January 2020
- preprint
- Published by Springer Nature in Research Square
Abstract
Background: During drilling of bone, which is common in clinical surgeries, heat generation increases local temperature in the drilling site. Transmission of excessive heat to the surrounding bone tissue can cause thermal osteonecrosis. Consequently, it may lead to failure of implants and fixation screws or delay in healing process. Using cooling is a method for limiting temperature elevation. Materials and Methods: In this study, through comparing 3 conditions of drilling without cooling, external cooling with normal saline, and external cooling with OpSite spray, the efficiency of OpSite as coolant is studied. In this regard, 2 drill bit diameters, 3 drilling speeds, and 3 drilling feed-rates are considered as drilling variables in the experiments. Results: For the whole experiments, while cooling with normal saline resulted in lower maximum temperatures than without cooling condition, OpSite had even better results and limited the temperature elevation during drilling of bone efficiently. Conclusion: OpSite spray, which has lower infection risks than normal saline on one hand and lower maximum temperature rise with all combinations of drilling parameters on the other hand, can be considered in clinical surgeries for cooling applications.Keywords
All Related Versions
- Published version: Journal of Orthopaedic Surgery and Research, 15 (1), 1.
This publication has 17 references indexed in Scilit:
- Thermal evaluation by infrared measurement of implant site preparation between single and gradual drilling in artificial bone blocks of different densitiesInternational Journal of Oral and Maxillofacial Surgery, 2016
- Experimental analysis of drilling process in cortical boneMedical Engineering & Physics, 2013
- Drilling of bone: A comprehensive reviewJournal of Clinical Orthopaedics and Trauma, 2013
- Influence of drill parameters on bone temperature and necrosis: A FEM modelling and in vitro experimentsComputational Materials Science, 2012
- Cortical bone drilling and thermal osteonecrosisClinical Biomechanics, 2012
- Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: An in vitro studyMedical Engineering & Physics, 2011
- Thermal osteonecrosis and bone drilling parameters revisitedArchives of orthopaedic and trauma surgery, 2007
- Effects of different cooling conditions on twist drill temperatureThe International Journal of Advanced Manufacturing Technology, 2006
- Influence of bone milling parameters on the temperature rise, milling forces and surface flatness in view of robot-assisted total knee arthroplastyInternational Congress Series, 2001
- Temperature effects in the drilling of human and bovine boneJournal of Materials Processing Technology, 1999