A self-paced walk test for individual calibration of heart rate to energy expenditure
Preprint
Abstract
Introduction: Estimating free-living physical activity (PA) with continuous heart rate (HR) monitoring is challenging due to individual variation in the relationship between HR and energy expenditure. This variation can be captured through individual calibration with graded exercise tests, but structured tests with prescribed load requires medical screening and are not always feasible in population settings. We present and evaluate an individual calibration method using HR response to a less demanding self-paced walk test. Methods: 643 participants from the Fenland Study (Cambridgeshire, UK) completed a 200-meter self-paced walk test, a treadmill test, and one week of continuous HR and accelerometry monitoring. Mixed effects regression was used to derive a walk test calibration model from HR response to the walk using treadmill-based parameters as criterion. Free-living PA estimates from the calibration model were compared with treadmill-calibrated as well as non-exercise calibrated estimates. Results: The walk calibration model captured 57% of the variance in the HR-energy expenditure relationship determined by the treadmill test. Applying the walk calibration method to data from free-living yielded similar PA estimates to those using treadmill calibration (52.7 vs 52.0 kJ·kg -1 ·day -1 ; mean difference: 0.7 kJ·kg -1 ·day -1 , 95% CI: −0.0, 1.5) and high correlation (r=0.89). Individual differences were observed (RMSE: 10.0 kJ·kg -1 ·day -1 ; 95% limits of agreement: −20.6, 19.1 kJ·kg -1 ·day -1 ). Compared to using a non-exercise group calibration model (RMSE: 14.0 kJ·kg -1 ·day -1 ; 95% limits of agreement: −30.4, 24.5 kJ·kg -1 ·day -1 ), the walk calibration improved precision by 29%. Conclusions: A 200-meter self-paced walk test captures a significant proportion of the between-individual variation in the HR-energy expenditure relationship and facilitates estimation of free-living PA in population settings.Keywords
All Related Versions
- Published version: Journal for the Measurement of Physical Behaviour, 7 (1), 12.
This publication has 28 references indexed in Scilit:
- The use of combined heart rate response and accelerometry to assess the level and predictors of physical activity in tuberculosis patients in TanzaniaEpidemiology and Infection, 2013
- Level and intensity of objectively assessed physical activity among pregnant women from urban EthiopiaBMC Pregnancy and Childbirth, 2012
- Measures of physical performance assessments: Self‐Paced Walk Test (SPWT), Stair Climb Test (SCT), Six‐Minute Walk Test (6MWT), Chair Stand Test (CST), Timed Up & Go (TUG), Sock Test, Lift and Carry Test (LCT), and Car TaskArthritis Care & Research, 2011
- Hierarchy of individual calibration levels for heart rate and accelerometry to measure physical activityJournal of Applied Physiology, 2007
- Childhood Obesity and Type 2 Diabetes MellitusPediatrics, 2005
- Reliability and validity of the combined heart rate and movement sensor ActiheartEuropean Journal of Clinical Nutrition, 2005
- Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditureJournal of Applied Physiology, 2004
- Measuring human energy expenditure: What have we learned from the flex‐heart rate method?American Journal of Human Biology, 2003
- Factors Affecting the Relation Between Heart Rate and Energy Expenditure During ExerciseInternational Journal of Sports Medicine, 1999
- The use of heart rate monitoring in the estimation of energy expenditure: a validation study using indirect whole-body calorimetryBritish Journal of Nutrition, 1989