Abstract
The objective of this research is to manufacture a flow measurement locally device for open channels and predict the discharge coefficient for two types of weirs, then compared its results with extracted from the standard device. Experimentally, two weirs shape were investigated, known as a V-notch with a right angle (90°) and a rectangular notch with a crest width (0.3m). The height of crest for both remained constant in locally and standard flow measurement device. In order to developing the hydraulic properties of flow over a crest weir and to achieve the study purpose, a different crest heads were investigated. Experimental results showed that the increase of crest head causes an increase in a discharge coefficient for both V-notch and rectangular weirs. In other words, the coefficient of discharge is dependent on the volumetric flow rate and its head of water level from the notch base, the discharge coefficient corresponds differently to the head of water level and to the notch type used. In flow measurement locally device, results show that local device has the ability to measure the hydraulic properties of flow over weir of open channel flow in both triangular and rectangular notch with an error percentage of Cd 9.3% and 6.56% for rectangular and V-Notch weir, respectively.