Modified MLEM Algorithm for Artifact Suppression in CT
- 1 January 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6 (10823654) , 3511-3518
Abstract
Iterative methods for CT image reconstruction are widely disregarded in clinical routine due to the inherent massive computational effort. On the other hand, the continuously growing computational power of today's standard computers has led to a rediscovery of these methods. Currently, filtered backprojection (FBP) is the reconstruction method of choice, because it is very fast, especially on dedicated hardware. However, a disadvantage of FBP is that it ignores some of the physical effects like beam hardening, scatter and noise, leading to artifacts in the reconstructed images. Artifacts of this type are particularly dominant if metal objects are inside the patient, because FBP interprets the corresponding projection data as inconsistent. For the method proposed here, the inconsistency of the metal-influenced projection data is reduced with an interpolation scheme working in the Radon-space domain. As the interpolation yields a vague estimate of the real soft-tissue projection values, residual inconsistencies remain. Those residuals can be treated by a modified maximum likelihood expectation maximization (MLEM) method presented in this paper. Within the novel approach, different projection lines through the object can be associated with appropriate weightings that decrease the influence of the residual inconsistencies - resulting in an overall image-quality enhancement. The approach is demonstrated on real CT measurements of a torso phantom equipped with metal markers that allows an evaluation with the corresponding ground truth data.Keywords
This publication has 45 references indexed in Scilit:
- Reduction of Attenuation Correction Artifacts in PET-CT2006
- Decoupling the equations of regularized tomography2003
- Deblurring subject to nonnegativity constraints when known functions are present with application to object-constrained computerized tomographyIEEE Transactions on Medical Imaging, 2001
- X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prosthesesIEEE Transactions on Medical Imaging, 2000
- Metal streak artifacts in X-ray computed tomography: a simulation studyIEEE Transactions on Nuclear Science, 1999
- Total Hip Prosthesis Metal-Artifact Suppression Using Iterative Deblurring ReconstructionJournal of Computer Assisted Tomography, 1997
- Iterative deblurring for CT metal artifact reductionIEEE Transactions on Medical Imaging, 1996
- Bayesian reconstructions from emission tomography data using a modified EM algorithmIEEE Transactions on Medical Imaging, 1990
- A Theoretical Study of Some Maximum Likelihood Algorithms for Emission and Transmission TomographyIEEE Transactions on Medical Imaging, 1987
- Maximum Likelihood Reconstruction for Emission TomographyIEEE Transactions on Medical Imaging, 1982