Modeling and development of screen-printed impedance biosensor for cytotoxicity studies of lung carcinoma cells
- 16 December 2017
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 56 (1) , 173-181
Abstract
Electrical cell-substrate impedance sensing (ECIS) is a powerful technique to monitor real-time cell behavior. In this study, an ECIS biosensor formed using two interdigitated electrode structures (IDEs) was used to monitor cell behavior and its response to toxicants. Three different sensors with varied electrode spacing were first modeled using COMSOL Multiphysics and then fabricated and tested. The silver/silver chloride IDEs were fabricated using a screen-printing technique and incorporated with polydimethylsiloxane (PDMS) cell culture wells. To study the effectiveness of the biosensor, A549 lung carcinoma cells were seeded in the culture wells together with collagen as an extracellular matrix (ECM) to promote cell attachment on electrodes. A549 cells were cultured in the chambers and impedance measurements were taken at 12-h intervals for 120 h. Cell index (CI) for both designs were calculated from the impedance measurement and plotted in comparison with the growth profile of the cells in T-flasks. To verify that the ECIS biosensor can also be used to study cell response to toxicants, the A549 cells were also treated with anti-cancer drug, paclitaxel, and its responses were monitored over 5 days. Both simulation and experimental results show better sensitivity for smaller spacing between electrodes. The fabricated impedance biosensor used screen-printed silver/silver chloride IDEs. Simulation and experimental results show better sensitivity for smaller between electrodes.Keywords
Funding Information
- Kementerian Sains, Teknologi dan Inovasi (SF16-004-0073)
This publication has 27 references indexed in Scilit:
- Electric Cell-Substrate Impedance Sensing Concept to Commercialization2012
- A microfluidic device with passive air-bubble valves for real-time measurement of dose-dependent drug cytotoxicity through impedance sensingBiosensors and Bioelectronics, 2012
- High spatial resolution impedance measurement of EIS sensors for light addressable cell adhesion monitoringBiosensors and Bioelectronics, 2011
- Electrical cell-substrate impedance sensing as a non-invasive tool for cancer cell studyThe Analyst, 2010
- Effects of negative pressures on epithelial tight junctions and migration in wound healingAmerican Journal of Physiology-Cell Physiology, 2010
- Cell Adhesion Monitoring Using Substrate-Integrated SensorsJournal of Adhesion Science and Technology, 2010
- Two-dimensional nanosecond electric field mapping based on cell electropermeabilizationPMC Biophysics, 2009
- Analysis of the sensitivity and frequency characteristics of coplanar electrical cell–substrate impedance sensorsBiosensors and Bioelectronics, 2008
- A cell-microelectronic sensing technique for profiling cytotoxicity of chemicalsAnalytica Chimica Acta, 2008
- Cellular impedance biosensors for drug screening and toxin detectionThe Analyst, 2007