Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study
- 23 October 2015
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 24 (S7) , 937-941
Abstract
Pedicle screw placement is an increasingly common procedure for the correction of spine degenerative disease, deformity and trauma. However, screw placement is demanding, with complications resulting from inaccurate screw placement. While several different techniques have been developed to improve accuracy, they all have their limitations. We examined the MySpine (Medacta International SA, Castel San Pietro, CH) patient-matched pedicle targeting guide in three cadaveric spine specimens operated on by three surgeons. A three-dimensional (3D) preoperative plan was constructed from spinal computed tomography scans, from which individualised guides were developed for the placement of Medacta Unconstrained Screw Technology pedicle screws. Following screw placement, the 3D positioning of the screws was compared to the preoperative plan against a series of pre-defined criteria. Of 46 inserted screws eligible for assessment, 91.3 % were fully inside the pedicle. There were no cases of Grade B (2–4 mm) or C (>4 mm) pedicle perforation. The mean deviation between the planned and actual screw position at the midpoint of the pedicle was 0.70 mm, the mean horizontal deviation was 0.60 mm and the mean vertical deviation was 0.77 mm. The mean angular deviation in the sagittal plane was 1.74°, versus 1.32° in the transverse plane. The mean deviation in screw depth was 1.55 mm. On all measures, the accuracy of screw placement was within the predefined criteria. Our cadaver study indicates that pedicle screw placement with the system is accurate and should be investigated in larger in vitro and in vivo studies.Keywords
This publication has 31 references indexed in Scilit:
- Worldwide Survey on the Use of Navigation in Spine SurgeryWorld Neurosurgery, 2013
- Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniquesEuropean Spine Journal, 2011
- Efficacy and accuracy of a novel rapid prototyping drill template for cervical pedicle screw placementComputer Aided Surgery, 2011
- Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniquesEuropean Spine Journal, 2011
- Quantitative analysis of misplaced pedicle screws in the thoracic spine: how much pullout strength is lost?Journal of Neurosurgery: Spine, 2010
- Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spineIndian Journal of Orthopaedics, 2010
- Image-guided pedicle screw insertion accuracy: a meta-analysisInternational Orthopaedics, 2009
- Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand techniqueInternational Orthopaedics, 2008
- Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literatureEuropean Spine Journal, 2008
- Pedicle Screw Placement AccuracySpine, 2007