Efficacy of Er:YAG laser irradiation for decontamination and its effect on biocompatibility of different titanium surfaces
Authors:
Open Access
- 18 December 2021
- journal article
- research article
- Published by Springer Nature in BMC Oral Health
- Vol. 21 (1) , 1-12
Abstract
Background: Erbium yttrium–aluminum–garnet (Er:YAG) laser have been shown to be suitable for decontamination of titanium surfaces at a wide range of energy settings, however, high intensity of laser irradiation destroy titanium surface and low intensity cannot remove enough microbial biofilm. The aim of this study was to investigate the optimal energy setting of Er:YAG laser for decontamination of sandblasted/acid-etched (SLA) and hydroxyapatite (HA) titanium surfaces. Material and methods: After supragingival biofilm construction in vivo, SLA and HA titanium discs were divided into three groups: blank control (BC, clean discs), experimental control (EC, contaminated discs) and experimental groups (EP, contaminated discs irradiated by Er:YAG laser at 40, 70, and 100 mJ/pulse). Scanning electron microscopy (SEM), live/dead bacterial fluorescent detection, and colony counting assay were used to detect the efficacy of laser decontamination. To investigate the effect of laser decontamination on titanium surface biocompatibility, MC3T3-E1 cell adhesion and proliferation activity were examined by SEM and CCK-8 assay. Results: Er:YAG laser irradiation at 100 mJ/pulse removed 84.1% of bacteria from SLA titanium surface; laser irradiation at 70 and 100 mJ/pulse removed 76.4% and 77.85% of bacteria from HA titanium surface respectively. Laser irradiation improved MC3T3-E1 cell adhesion on both titanium surfaces. For SLA titanium discs, 100 mJ/pulse group displayed excellent cellular proliferation activity higher than that in BC group (P < 0.01). For HA titanium discs, 70 mJ/pulse group showed the highest activity comparable to BC group (P > 0.05). Conclusions: With regards to efficient microbial biofilm decontamination and biocompatibility maintenance, Er:YAG laser at 100 mJ/pulse and 70 mJ/pulse are considered as the optimal energy settings for SLA titanium and HA titanium surface respectively. This study provides theoretical basis for the clinical application of Er:YAG laser in the treatment of peri-implantitis.Keywords
Funding Information
- Basic Research Project of Sichuan Provincial Department of Science and Technology (20YYJC3660)
This publication has 38 references indexed in Scilit:
- The Effects of Er:YAG Laser Treatment on Titanium Surface Profile and Osteoblastic Cell Activity: An In Vitro StudyJournal of Periodontology, 2011
- The effect of Er:YAG laser irradiation on the scanning electron microscopic structure and surface roughness of various implant surfaces: an in vitro studyLasers in Medical Science, 2010
- Comparative biology of chronic and aggressive periodontitis vs. peri-implantitisPeriodontology 2000, 2010
- Subgingival biofilm formationPeriodontology 2000, 2009
- Bacterial Adhesion on Smooth and Rough Titanium Surfaces After Treatment With Different InstrumentsJournal of Periodontology, 2009
- The impact of laser application on periodontal and peri‐implant wound healingPeriodontology 2000, 2009
- High surface energy enhances cell response to titanium substrate microstructureJournal of Biomedical Materials Research Part A, 2005
- Influence of different treatment approaches on the removal of early plaque biofilms and the viability of SAOS2 osteoblasts grown on titanium implantsClinical Oral Investigations, 2005
- Effects of the Er:YAG Laser Irradiation on Titanium Implant Materials and Contaminated Implant Abutment SurfacesJournal of Clinical Laser Medicine & Surgery, 2003
- Resolution of peri‐implantitis following treatment. An experimental study in the dog.Clinical Oral Implants Research, 1999