Imaging the Internal Auditory Canal with an 8 × 2 Transceiver Array Head Coil at 7T
- 27 March 2025
- journal article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (4) , 852-858
Abstract
SUMMARY: 7T neuroimaging has known problems with B1+ strength, homogeneity and B0 susceptibility that make imaging in the inferior brain regions difficult. We investigated the utility of a decoupled 8 × 2 transceiver coil and shim insert to image the internal auditory canal (IAC) and inferior brain in comparison to the standard Nova 8/32 coil. B1+, B0, and the T2 sampling perfection with application-optimized contrasts by using flip angle evolution sequence (SPACE) were compared by using research and standard methods in n = 8 healthy adults by using a Terra system. A T2 TSE was also acquired, and 2 neuroradiologists evaluated structures in and around the IAC, blinded to the acquisition, by using a 5-point Likert scale. The Nova 8/32 coil gave lower B1+ inferiorly compared with the whole brain while the transceiver maintained similar B1+ throughout. SPACE images showed that the transceiver performed significantly better, e.g., the transceiver scored 4.0 ± 0.8 in the left IAC, compared with 2.5 ± 0.8 with the Nova 8/32. With T2-weighted imaging that places a premium on refocusing pulses, these results show that with improved B1+ performance inferiorly, good visualization of the structure of the IAC and inferior brain regions is possible at 7T. Graphical AbstractKeywords
Funding Information
- Common Fund (NIH NIBIB EB024408)
This publication has 16 references indexed in Scilit:
- Evaluation of the performance of a 7‐T 8 × 2 transceiver arrayNMR in Biomedicine, 2024
- Electromagnetic simulation of a 16‐channel head transceiver at 7 T using circuit‐spatial optimizationMagnetic Resonance in Medicine, 2021
- Dynamic B0 shimming for multiband imaging using high order spherical harmonic shimsMagnetic Resonance in Medicine, 2020
- Role of very high order and degree B0 shimming for spectroscopic imaging of the human brain at 7 teslaMagnetic Resonance in Medicine, 2011
- Transceiver-Phased Arrays for Human Brain Studies at 7 TApplied Magnetic Resonance, 2011
- A radiofrequency coil to facilitate B shimming and parallel imaging acceleration in three dimensions at 7 TNMR in Biomedicine, 2010
- Spatial domain method for the design of RF pulses in multicoil parallel excitationMagnetic Resonance in Medicine, 2006
- Transmit SENSEMagnetic Resonance in Medicine, 2002
- 7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head imagesMagnetic Resonance in Medicine, 2001
- Three‐dimensional mapping of the static magnetic field inside the human headMagnetic Resonance in Medicine, 1996