Abstract
Peptides have enormous potential as therapeutic agents for the treatment of infection, in immunomodulation and for other medical applications, but their hydrolytic degradation in biological fluids is a serious limitation to their in vivo performance. Here we demonstrate the potential utility of polyelectrolyte nanoparticle complexes of novel self‐assembling anionic graft copolymers for protecting peptides from degradation in human plasma. The anionic graft copolymers are synthesized by covalently attaching pendent polyetheramine chains to poly(alkylacrylic acid) backbones by carbodiimide coupling. The peptide:copolymer nanocomplexes' particle size, zeta‐potential, peptide binding, and controlled release of the peptide are shown to be dependent upon the pendent chain graft density, polymer backbone alkyl groups (propyl vs. methyl), and the nanocomplexes' electrostatic charge ratio. The nanocomplexes can provide substantial protection to the bound peptides from degradation in human plasma for at least 24 h and, in standard microbiological assays are shown to retain some or all of the peptide's antimicrobial activity against a clinically relevant strain of Staphylococcus aureus. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 101A: 2548–2558, 2013.