Three‐dimensional whole‐brain mapping of cerebral blood volume and venous cerebral blood volume using Fourier transform–based velocity‐selective pulse trains
Open Access
- 6 May 2021
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (3) , 1420-1433
Abstract
Purpose: To develop 3D MRI methods for cerebral blood volume (CBV) and venous cerebral blood volume (vCBV) estimation with whole‐brain coverage using Fourier transform–based velocity‐selective (FT‐VS) pulse trains.Methods: For CBV measurement, FT‐VS saturation pulse trains were used to suppress static tissue, whereas CSF contamination was corrected voxel‐by‐voxel using a multi‐readout acquisition and a fast CSF T2 scan. The vCBV mapping was achieved by inserting an arterial‐nulling module that included a FT‐VS inversion pulse train. Using these methods, CBV and vCBV maps were obtained on 6 healthy volunteers at 3 T.Results: The mean CBV and vCBV values in gray matter and white matter in different areas of the brain showed high correlation (r = 0.95 and P < .0001). The averaged CBV and vCBV values of the whole brain were 5.4 ± 0.6 mL/100 g and 2.5 ± 0.3 mL/100 g in gray matter, and 2.6 ± 0.5 mL/100 g and 1.5 ± 0.2 mL/100 g in white matter, respectively, comparable to the literature.Conclusion: The feasibility of FT‐VS‐based CBV and vCBV estimation was demonstrated for 3D acquisition with large spatial coverage.Keywords
Funding Information
- National Institutes of Health (K25 HL145129, P41 EB015909, R01 HL138182, R01 HL144751, S10 OD021648)
- American Society of Hematology
This publication has 62 references indexed in Scilit:
- QUantitative Imaging of eXtraction of oxygen and TIssue consumption (QUIXOTIC) using venular‐targeted velocity‐selective spin labelingMagnetic Resonance in Medicine, 2011
- Measurement of absolute arterial cerebral blood volume in human brain without using a contrast agentNMR in Biomedicine, 2011
- Calibration and validation of TRUST MRI for the estimation of cerebral blood oxygenationMagnetic Resonance in Medicine, 2011
- Temporal Dynamics and Spatial Specificity of Arterial and Venous Blood Volume Changes during Visual Stimulation: Implication for Bold QuantificationJournal of Cerebral Blood Flow & Metabolism, 2010
- Fast measurement of bloodT1in the human jugular vein at 3 TeslaMagnetic Resonance in Medicine, 2010
- Determination of whole‐brain oxygen extraction fractions by fast measurement of blood T2 in the jugular veinMagnetic Resonance in Medicine, 2010
- In vivo venous blood T1 measurement using inversion recovery true‐FISP in children and adultsMagnetic Resonance in Medicine, 2010
- A Fully Automated Method for Quantitative Cerebral Hemodynamic Analysis Using DSC–MRIJournal of Cerebral Blood Flow & Metabolism, 2010
- On the measurement of absolute cerebral blood volume (CBV) using vascular‐space‐occupancy (VASO) MRIMagnetic Resonance in Medicine, 2008
- Quantitative evaluation of oxygenation in venous vessels using T2‐Relaxation‐Under‐Spin‐Tagging MRIMagnetic Resonance in Medicine, 2008