Current Reference Control for Shunt Active Power Filters Under Unbalanced and Distorted Supply Voltage Conditions
Open Access
- 5 December 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 177048-177055
Abstract
This paper proposes a current reference control method for shunt active power filter under unbalanced and distorted supply voltage conditions. The method uses the Kalman filter and the symmetrical component method to obtain the fundamental sequence component of the supply voltage. The Fryze-Buchholz-Dpenbrock method is used to decompose the load current under the reference of the fundamental positive-sequence voltage to obtain the reference value of the compensation current. The method is characterized without need of coordinate transformation, simple calculation, and clear physical meaning. The harmonic current, reactive current and negative sequence current can be compensated at the same time even under the condition of unbalanced supply voltage. The proposed method is compared with the traditional method under various experimental conditions to prove the validity and accuracy of the proposed method. The results show that the proposed method has wider applicability.Keywords
Funding Information
- National Natural Science Foundation of China (51467013, 51867017)
This publication has 25 references indexed in Scilit:
- Constraints of instantaneous reactive power p − q theoryIET Power Electronics, 2014
- Optimal Control of Shunt Active Power Filter to Meet IEEE Std. 519 Current Harmonic Constraints Under Nonideal Supply ConditionIEEE Transactions on Industrial Electronics, 2014
- Analysis, design and digital implementation of a shunt active power filter with different schemes of reference current generationIET Power Electronics, 2014
- Space vector modulation strategy for neutral‐point voltage balancing in three‐level inverter systemsIET Power Electronics, 2013
- A DSP-Based Implementation of the $p{\hbox{–}}q$ Theory in Active Power Filtering Under Nonideal Voltage ConditionsIEEE Transactions on Industrial Informatics, 2012
- Real-time implementation of adaptive fuzzy hysteresis-band current control technique for shunt active power filterIET Power Electronics, 2012
- Hysteresis current control of hybrid active power filtersIET Power Electronics, 2012
- Working, reflected and detrimental active powersIET Generation, Transmission & Distribution, 2012
- The FBD-method, a generally applicable tool for analyzing power relationsIEEE Transactions on Power Systems, 1993
- Powers in nonsinusoidal networks: their interpretation, analysis, and measurementIEEE Transactions on Instrumentation and Measurement, 1990