Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand
- 11 November 2009
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 35 (1) , 19-24
Abstract
Leg length discrepancy following total hip replacement (THR) can contribute to poor hip function. Abnormal gait, pain, neurological disturbance and patient dissatisfaction have all been described as a result of leg length inequality after THR. The purpose of this study was to determine whether the use of computer navigation in THR can improve limb length restoration and early clinical outcomes. We performed a matched-pair study comparing 48 computer-assisted THR with 48 THRs performed using a traditional freehand alignment method. The same implant with a straight non-modular femoral stem was used in all cases. The navigation system used allowed the surgeon to monitor both acetabular cup placement and all the phases of femoral stem implantation including rasping. Patients were matched for age, sex, arthritis level, pre-operative diagnosis and pre-operative leg length discrepancy. At a minimum follow-up of six months, limb length discrepancy was measured using digital radiographs and a standardised protocol. The number of patients with a residual discrepancy of 10 mm or more and/or a post-operative over-lengthening were measured. The clinical outcome was evaluated using both the Harris Hip Score and the normalised Western Ontario and McMaster Universities (WOMAC) Arthritis Index. Restoration of limb length was significantly better in the computer-assisted THR group. The number of patients with a residual limb length discrepancy greater than 10 mm and/or a post-operative over-lengthening was significantly lower. No significant difference in the Harris Hip Score or normalised WOMAC Arthritis Index was seen between the two groups. The surgical time was significantly longer in the computer-assisted THR group. No post-operative dislocations were seen.Keywords
This publication has 34 references indexed in Scilit:
- Measuring leg length and offset with an imageless navigation system during total hip arthroplasty: is it really accurate?The International Journal of Medical Robotics and Computer Assisted Surgery, 2009
- Prevalence and functional impact of patient-perceived leg length discrepancy after hip replacementInternational Orthopaedics, 2008
- Computer navigation in total hip replacement: a meta-analysisInternational Orthopaedics, 2008
- Accuracy of imageless stem navigation during simulated total hip arthroplastyActa Orthopaedica, 2008
- Navigated non-image-based positioning of the acetabulum during total hip replacementInternational Orthopaedics, 2007
- Clinical Outcome of Total Hip Arthroplasty Using the Normalized and Proportionalized Femoral Stem With a Minimum 20-Year Follow-UpThe Journal of Arthroplasty, 2007
- Imageless navigation for insertion of the acetabular component in total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2006
- A simple method to minimize limb-length discrepancy after hip arthroplastyActa Orthopaedica, 2006
- The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplastiesActa Orthopaedica, 2000
- Radiological Assessment of Osteo-ArthrosisAnnals of the Rheumatic Diseases, 1957