The association between novel clinical factors and gastrointestinal bleeding among patients supported with continuous‐flow left ventricular assist device therapy
Authors:
- 6 May 2019
- journal article
- research article
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (6) , 453-462
Abstract
Background This study explores novel preimplantation risk factors associated with gastrointestinal bleeding (GIB) after continuous‐flow left ventricular assist device (CF‐LVAD) implantation. CF‐LVAD therapy implantation for patients with advanced heart failure is associated with a 20% to 40% incidence of GIB. Methods This study includes patients receiving CF‐LVAD at a quaternary medical center from 2006 to 2014 (n = 254). The primary endpoint was GIB within 12 months after implantation; the secondary outcome was 3‐year all‐cause mortality. The Student t test or the χ2 test compared continuous or categorical variables. Competing risks analysis calculated the cumulative incidence of GIB postimplantation. Cox proportional hazards model was used for univariate/multivariate models predicting GIB. Results Sixty‐four patients had GIB, with incidence rates at 1, 3, and 12 months of 11.8%, 19.3%, and 25.2%, respectively. Endoscopy revealed no identified source of bleeding in 41%; 33% of lesions were localized in the upper gastrointestinal tract, with the bulk (39%) categorized as vascular. Patients with prior gastrointestinal abnormalities (n = 98) had a greater risk of GIB post‐CF‐LVAD (HR 1.85 [1.11‐3.09]; P = 0.02) than those with normal gastrointestinal evaluation results (n = 45) and those without preimplantation gastrointestinal evaluation (n = 111). Baseline blood urea nitrogen, chronic obstructive pulmonary disease, and prior percutaneous coronary intervention were statistically associated with post‐CF‐LVAD GIB. The presence of GIB within 12 months of CF‐LVAD implantation was associated with an increased risk of 3‐year all‐cause mortality (HR 2.57 [1.57‐4.15]; P < 0.01). Conclusions First‐year GIB is associated with increased mortality post‐CF‐LVAD. We advocate a closer examination of several GIB risk factors when evaluating CF‐LVAD candidates.Keywords
This publication has 27 references indexed in Scilit:
- Gastrointestinal bleeding with the HeartMate II left ventricular assist deviceThe Journal of Heart and Lung Transplantation, 2012
- Chronic obstructive pulmonary disease: an independent risk factor for peptic ulcer bleeding: a nationwide population‐based studyAlimentary Pharmacology & Therapeutics, 2012
- Heart Disease and Stroke Statistics—2012 UpdateCirculation, 2012
- Mechanisms of Bleeding and Approach to Patients With Axial-Flow Left Ventricular Assist DevicesCirculation: Heart Failure, 2011
- Lessons Learned From Experience With Over 100 Consecutive HeartMate II Left Ventricular Assist DevicesThe Annals of Thoracic Surgery, 2011
- Acquired von Willebrand Syndrome After Continuous-Flow Mechanical Device Support Contributes to a High Prevalence of Bleeding During Long-Term Support and at the Time of TransplantationJACC, 2010
- Acquired von Willebrand Syndrome in Continuous-Flow Ventricular Assist Device RecipientsThe Annals of Thoracic Surgery, 2010
- Improved Survival of Patients With End-Stage Heart Failure Listed for Heart TransplantationJACC, 2007
- Use of a Continuous-Flow Device in Patients Awaiting Heart TransplantationNew England Journal of Medicine, 2007
- Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart FailureThe New England journal of medicine, 2001