Doppler Ultrasound Imaging Combined with Fetal Heart Detection in Predicting Fetal Distress in Pregnancy-Induced Hypertension under the Guidance of Artificial Intelligence Algorithm
Open Access
- 8 October 2021
- journal article
- retracted article
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2021, 1-10
Abstract
This study was to improve the feasibility and economic benefits of intelligent medical system Doppler ultrasound (DUS) imaging technology combined with fetal heart detection to predict the fetal distress in pregnancy-induced hypertension (PIH), so as to reduce the risk of deterioration of the patient’s condition. The characteristics of DUS images were analyzed, and a diffusion filter reducing the specificity was adopted to improve the smooth speckle noise of DUS images. 120 pregnant women in hospital were the subjects of the study, all of whom received ultrasound cord blood flow testing and fetal heart monitoring. 88 PIH patients with fetal distress were diagnosed and included in the observation group, and 32 healthy pregnant women tested during the same period were identified as the control group. Clinical data were reviewed and analyzed. The diagnostic rates of fetal distress by simple fetal heart monitoring and DUS detection combined with fetal heart monitoring were compared. The results showed that 26.7% of fetal distress were diagnosed by fetal heart monitoring alone, and 73.3% of fetal distress were diagnosed by combined testing, so the diagnostic accuracy of the combined detection method was greatly higher than the single fetal heart detection ( ). The Pulsatility index (PI), resistance index (RI), and S/D values detected by the umbilical artery in the observation group were 1.48, 0.85, and 4.31, respectively. The PI, RI, and S/D values detected by the umbilical artery in the control group were 0.96, 0.64, and 3.59, respectively. The results of arterial detection were significantly higher than those of the control group, and the difference was of significant scientific significance ( ). In summary, the PI and RI values of the middle cerebral artery (MCA) detected by DUS diagnosis can effectively reflect the current status of the fetus in the uterus and reduce the mortality of the fetus. The images guided by DUS imaging technology can clearly show the current status of the fetus in the uterus, effectively improve the medical diagnostic efficiency, and have important reference value for the development of intelligent medical equipment.Keywords
Funding Information
- Joint Guidance Project of Science and Technology Plan of Qiqihar (LHYD-2021052)
This publication has 21 references indexed in Scilit:
- Accuracy of the fetal cerebroplacental ratio for the detection of intrapartum compromise in nonsmall fetusesThe Journal of Maternal-Fetal & Neonatal Medicine, 2018
- Kristeller maneuvers or fundal pressure and maternal/neonatal morbidity: obstetric and judicial literature reviewThe Journal of Maternal-Fetal & Neonatal Medicine, 2018
- Detection rate of fetal distress using contraction-dependent fetal heart rate variability analysisPhysiological Measurement, 2018
- Combined use of serum gamma glutamyl transferase level and ultrasonography improves prediction of perinatal outcomes associated with preeclamptic pregnancyClinica Chimica Acta, 2017
- Cerebral NIRS patterns in late preterm and very preterm infants becoming late pretermThe Journal of Maternal-Fetal & Neonatal Medicine, 2017
- Prenatal, perinatal, and postnatal factors associated with autismMedicine, 2017
- Association between polycystic ovary syndrome and the risk of pregnancy complicationsMedicine, 2016
- Metformin in women with type 2 diabetes in pregnancy (MiTy): a multi-center randomized controlled trialBMC Pregnancy and Childbirth, 2016
- Prospective evaluation of multiparametric ultrasound and quantitative elastosonography in the differential diagnosis of benign and malignant thyroid nodules: Preliminary experienceEuropean Journal of Radiology, 2012