Cartilage Endplate Thickness Variation Measured by Ultrashort Echo-Time MRI Is Associated With Adjacent Disc Degeneration
Authors:
- 15 May 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 43 (10) , E592-E600
Abstract
Study Design.: A magnetic resonance imaging study of human cadaver spines. Objective.: To investigate associations between cartilage endplate (CEP) thickness and disc degeneration. Summary of Background Data.: Damage to the CEP is associated with spinal injury and back pain. However, CEP morphology and its association with disc degeneration have not been well characterized. Methods.: Ten lumbar motion segments with varying degrees of disc degeneration were harvested from six cadaveric spines and scanned with magnetic resonance imaging in the sagittal plane using a T2-weighted two-dimensional (2D) sequence, a three-dimensional (3D) ultrashort echo-time (UTE) imaging sequence, and a 3D T1ρ mapping sequence. CEP thicknesses were calculated from 3D UTE image data using a custom, automated algorithm, and these values were validated against histology measurements. Pfirrmann grades and T1ρ values in the disc were assessed and correlated with CEP thickness. Results.: The mean CEP thickness calculated from UTE images was 0.74 ± 0.04 mm. Statistical comparisons between histology and UTE-derived measurements of CEP thickness showed significant agreement, with the mean difference not significantly different from zero (P = 0.32). Within-disc variation of T1ρ (standard deviation) was significantly lower for Pfirrmann grade 4 than Pfirrmann grade 3 (P < 0.05). Within-disc variation of T1ρ and adjacent CEP thickness heterogeneity (coefficient of variation) had a significant negative correlation (r = −0.65, P = 0.04). The standard deviation of T1ρand the mean CEP thickness showed a moderate positive correlation (r = 0.40, P = 0.26). Conclusion.: This study demonstrates that quantitative measurements of CEP thickness measured from UTE magnetic resonance imaging are associated with disc degeneration. Our results suggest that variability in CEP thickness and T1ρ, rather than their mean values, may serve as valuable diagnostic markers for disc degeneration. Level of Evidence: N/AKeywords
This publication has 40 references indexed in Scilit:
- In vivo 3.0‐tesla magnetic resonance T1ρ and T2 relaxation mapping in subjects with intervertebral disc degeneration and clinical symptomsMagnetic Resonance in Medicine, 2010
- In vivo T1ρ mapping in cartilage using 3D magnetization‐prepared angle‐modulated partitioned k‐space spoiled gradient echo snapshots (3D MAPSS)Magnetic Resonance in Medicine, 2008
- What is Intervertebral Disc Degeneration, and What Causes It?Spine, 2006
- Measurement and analyses of the effects of adjacent end plate curvatures on vertebral stressesThe Spine Journal, 2006
- In vivo quantification of human lumbar disc degeneration using T1ρ-weighted magnetic resonance imagingEuropean Spine Journal, 2006
- Transport Properties of the Human Cartilage Endplate in Relation to Its Composition and CalcificationSpine, 1996
- Compressive properties of the cartilaginous end‐plate of the baboon lumbar spineJournal of Orthopaedic Research, 1993
- Correlating magnetic resonance imaging with the biochemical content of the normal human intervertebral discJournal of Orthopaedic Research, 1992
- Nutrition of the Intervertebral DiskClinical Orthopaedics and Related Research, 1977
- In Vitro Diffusion of DYE Through the End-Plates and the Annulus Fibrosus of Human Lumbar Inter-Vertebral DiscsActa Orthopaedica, 1970