Operation of high power cycloconverter-fed gearless drives under abnormal conditions
Authors:
- J. RodriguezJ. Rodriguez
- K. TischlerKTK. Tischler
- N. BeckerNBN. Becker
- J. RebolledoJRJ. Rebolledo
- 8 November 2004
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1083-1089 vol.2
Abstract
This paper presents the behavior of large power mills (more than 10 MW each) fed by cycloconverters. Special attention is dedicated to the protection philosophy to avoid operational interruptions which can produce huge production losses and equipment damage. Several failure possibilities are considered: control failure, complete power outage, if a thyristor fails and cannot block reverse voltage, etc. Simulation studies and field measurements show that large currents and torque can occur under certain circumstances and that motor foundations must be able to support them. As a general conclusion, it can be said that proper protective design effectively avoids equipment damage.Keywords
This publication has 4 references indexed in Scilit:
- Technical evaluation and practical experience of high power grinding mill drives in mining applications2004
- Large static converters for industry and utility applicationsProceedings of the IEEE, 2001
- 15000-HP gearless ball mill drive in cement-why not!IEEE Transactions on Industry Applications, 1996
- High-power industrial drivesProceedings of the IEEE, 1994