Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces
Open Access
Abstract
The germicidal efficacy of LED UV-A lighting has scarcely been compared in continuous and pulsed modes for contaminated surfaces. Herein, we compare the disinfection properties of pulsed versus continuous lighting at equal irradiances using a 365 nm LED device that replicates the doses of occupied-space continuous disinfection UV-A products. Representative organisms evaluated in this study included human-infectious enveloped and non-enveloped viruses (lentivirus and adeno-associated virus, respectively), a bacterial endospore (Bacillus atrophaeus), and a resilient gram-positive bacterium (Enterococcus faecalis). Nominal UV-A irradiances were tested at or below the UL standard limit for continuous human exposure (maximum irradiance of 10 W/m2). We observed photoinactivation properties that varied by organism type, with bacteria and enveloped virus being more susceptible to UV-A than non-enveloped virus and spores. Overall, we conclude that continuous-mode UV-A lighting is better suited for occupied-space disinfection than pulsing UV-A at equivalent low irradiances, and we draw comparisons to other studies in the literature.Keywords
Funding Information
- Current
This publication has 31 references indexed in Scilit:
- Does improving surface cleaning and disinfection reduce health care-associated infections?American Journal of Infection Control, 2013
- Sustained Reduction of Microbial Burden on Common Hospital Surfaces through Introduction of CopperJournal of Clinical Microbiology, 2012
- Enhanced germicidal effects of pulsed UV-LED irradiation on biofilmsJournal of Applied Microbiology, 2010
- The respiratory chain is the cell's Achilles' heel during UVA inactivation in Escherichia coliMicrobiology, 2010
- Effect of UVA irradiance on photocatalytic and UVA inactivation of Bacillus cereus sporesJournal of Photochemistry and Photobiology B: Biology, 2009
- Improving Cleaning of the Environment Surrounding Patients in 36 Acute Care HospitalsInfection Control & Hospital Epidemiology, 2008
- Controlled inactivation of recombinant viruses with vitamin B2Journal of Virological Methods, 2008
- Development of a new water sterilization device with a 365 nm UV-LEDMedical & Biological Engineering & Computing, 2007
- The episkin phototoxicity assay (EPA): Development of an in vitro tiered strategy using 17 reference chemicals to predict phototoxic potencyToxicology in Vitro, 2007
- Riboflavin activated by ultraviolet A1 irradiation induces oxidative DNA damage-mediated mutations inhibited by vitamin CProceedings of the National Academy of Sciences, 2007