Occurrence of chlorine-resistant Pseudomonas aeruginosa in hospital water systems: threat of waterborne infections for patients
Open Access
- 27 September 2024
- journal article
- research article
- Published by Springer Nature in Antimicrobial Resistance & Infection Control
- Vol. 13 (1) , 1-10
Abstract
Several healthcare-associated infection outbreaks have been caused by waterborne Pseudomonas aeruginosa exhibiting its ability to colonize water systems and resist conventional chlorine treatment. This study aims to investigate the occurrence of Pseudomonas aeruginosa in hospital drinking water systems and the antimicrobial resistance profiles (antibiotic and chlorine resistance) of isolated strains. We investigated the presence of Pseudomonas aeruginosa in water and biofilms developed in nine hospital water systems (n = 192) using culture-based and molecular methods. We further assessed the survival of isolated strains after exposure to 0.5 and 1.5 ppm concentrations of chlorine. The profile of antibiotic resistance and presence of antibiotic resistance genes in isolated strains were also investigated. Using direct PCR method, Pseudomonas aeruginosa was detected in 22% (21/96) of water and 28% (27/96) of biofilm samples. However, culturable Pseudomonas aeruginosa was isolated from 14 samples. Most of P. aeruginosa isolates (86%) were resistant to at least one antibiotic (mainly β-lactams), with 50% demonstrating multidrug resistance. Moreover, three isolates harbored intI1 gene and two isolates contained blaOXA−24,blaOXA−48, and blaOXA−58 genes. Experiments with chlorine disinfection revealed that all tested Pseudomonas aeruginosa strains were resistant to a 0.5 ppm concentration. However, when exposed to a 1.5 ppm concentration of chlorine for 30 min, 60% of the strains were eliminated. Interestingly, all chlorine-resistant bacteria that survived at 30-minute exposure to 1.5 ppm chlorine were found to harbor the intI1 gene. The detection of antimicrobial resistant Pseudomonas aeruginosa in hospital water systems raises concerns about the potential for infections among hospitalized patients. The implementation of advanced mitigation measures and targeted disinfection methods should be considered to tackle the evolving challenges within hospital water systems.Keywords
Funding Information
- Kashan University of Medical Sciences (400188)
This publication has 47 references indexed in Scilit:
- Effect of water reservoirs types on the prevalence and antibiotic resistance profiles of Pseudomonas aeruginosa isolated from bathroom water in hospitalsJournal of Advanced Pharmaceutical Technology & Research, 2021
- The role of hospital environment in transmissions of multidrug-resistant gram-negative organismsAntimicrobial Resistance & Infection Control, 2020
- β-Lactamases and β-Lactamase Inhibitors in the 21st CenturyJournal of Molecular Biology, 2019
- Prevalence of blaOxacillinase-23and blaOxacillinase-24/40-type Carbapenemases in Pseudomonas aeruginosa Species Isolated From Patients With Nosocomial and Non-nosocomial Infections in the West of Iran2018
- Post-Outbreak Investigation of Pseudomonas aeruginosa Faucet Contamination by Quantitative Polymerase Chain Reaction and Environmental Factors Affecting PositivityInfection Control & Hospital Epidemiology, 2015
- OXA β-LactamasesClinical Microbiology Reviews, 2014
- Investigation of healthcare-acquired infections associated with Pseudomonas aeruginosa biofilms in taps in neonatal units in Northern IrelandJournal of Hospital Infection, 2014
- Rapid monitoring ofPseudomonas aeruginosain hospital water systems: a key priority in prevention of nosocomial infectionFEMS Microbiology Letters, 2013
- Association between Contaminated Faucets and Colonization or Infection by Nonfermenting Gram-Negative Bacteria in Intensive Care Units in TaiwanJournal of Clinical Microbiology, 2009
- Bad Bugs, No Drugs: No ESKAPE! An Update from the Infectious Diseases Society of AmericaClinical Infectious Diseases, 2009