Assessing normal pulse wave velocity in the proximal pulmonary arteries using transit time: A feasibility, repeatability, and observer reproducibility study by cardiovascular magnetic resonance
Authors:
Open Access
- 24 April 2007
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 25 (5) , 974-981
Abstract
Purpose: To calculate pulse wave velocity (PWV) in the proximal pulmonary arteries (PAs) by cardiovascular magnetic resonance (CMR) using the transit‐time method, and address respiratory variation, repeatability, and observer reproducibility.Materials and Methods: A 1.9‐msec interleaved phase velocity sequence was repeated three times consecutively in 10 normal subjects. Pulse wave (PW) arrival times (ATs) were determined for the main and branch PAs. The PWV was calculated by dividing the path length traveled by the difference in ATs. Respiratory variation was considered by comparing acquisitions with and without respiratory gating.Results: For navigated data the mean PWVs for the left PA (LPA) and right PA (RPA) were 2.09 ± 0.64 m/second and 2.33 ± 0.44 m/second, respectively. For non‐navigated data the mean PWVs for the LPA and RPA were 2.14 ± 0.41 m/second and 2.31 ± 0.49 m/second, respectively. No statistically significant difference was found between respiratory non‐navigated data and navigated data. Repeated on‐table measurements were consistent (LPA non‐navigated P = 0.95, RPA non‐navigated P = 0.91, LPA navigated P = 0.96, RPA navigated P = 0.51). The coefficients of variation (CVs) were 12.2% and 12.5% for intra‐ and interobserver assessments, respectively.Conclusion: One can measure PWV in the proximal PAs using transit‐time in a reproducible manner without respiratory gating. J. Magn. Reson. Imaging 2007;25:974–981.Keywords
This publication has 23 references indexed in Scilit:
- Magnetic resonance imaging guided catheterisation for assessment of pulmonary vascular resistance: in vivo validation and clinical application in patients with pulmonary hypertensionHeart, 2005
- A comparison of noninvasive MRI‐based methods of estimating pulmonary artery pressure in pulmonary hypertensionJournal of Magnetic Resonance Imaging, 2005
- Rapid measurement of pulse wave velocity via multisite flow displacementMagnetic Resonance in Medicine, 2004
- End points and clinical trial designs in pulmonary arterial hypertensionJACC, 2004
- A computed method for noninvasive MRI assessment of pulmonary arterial hypertensionJournal of Applied Physiology, 2004
- Assessment of Arterial Distensibility by Automatic Pulse Wave Velocity MeasurementHypertension, 1995
- Pulmonary artery distensibility and blood flow patterns: A magnetic resonance study of normal subjects and of patients with pulmonary arterial hypertensionAmerican Heart Journal, 1989
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Pulmonary Arterial Pulse Wave Velocity and Impedance in ManCirculation Research, 1969
- The velocity of pulse wave in manProceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character, 1922