Management of Neurosurgical Instruments and Patients Exposed to Creutzfeldt-Jakob Disease
Authors:
- 1 December 2013
- journal article
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 34 (12) , 1272-1280
Abstract
Objective.: To summarize the approaches used to manage exposure of patients to inadequately sterilized neurosurgical instruments contaminated as a result of Creutzfeldt-Jakob disease (CJD).Methods.: Information on past CJD exposure incidents reported to the Centers for Disease Control and Prevention (CDC) was aggregated and summarized. In addition, inactivation studies were reviewed, and data from selected publications were provided for reference.Results.: Nineteen incidents of patient exposure to potentially CJD-contaminated instruments were reported to the CDC, including 17 that involved intracranial procedures and 2 that involved ophthalmologic procedures. In more than 50% of incidents, the neurosurgical procedures were performed for diagnostic work up of the index patients. At least 12 of the hospitals had multiple neurosurgical sets, and the CJD-contaminated instruments could not be identified in 11 of 19 hospitals. In 12 of 15 hospitals with neurosurgical incidents, a decision was made to notify patients of their potential exposure.Conclusions.: Neurosurgical instruments used for treatment of patients with suspected or diagnosed CJD or patients whose diagnosis is unclear should be promptly identified and sterilized using recommended CJD decontamination protocols. Inability to trace instruments complicates appropriate management of exposure incidents. The feasibility of instituting instrument tracking procedures should be considered.Keywords
This publication has 33 references indexed in Scilit:
- Iatrogenic Creutzfeldt-Jakob Disease, Final AssessmentEmerging Infectious Diseases, 2012
- Real time quaking‐induced conversion analysis of cerebrospinal fluid in sporadic Creutzfeldt–Jakob diseaseAnnals of Neurology, 2012
- Disinfection and Sterilization of Prion-Contaminated Medical InstrumentsInfection Control & Hospital Epidemiology, 2010
- Guideline for Disinfection and Sterilization of Prion-Contaminated Medical InstrumentsInfection Control & Hospital Epidemiology, 2010
- New hospital disinfection processes for both conventional and prion infectious agents compatible with thermosensitive medical equipmentJournal of Hospital Infection, 2009
- Resistance of Bovine Spongiform Encephalopathy (BSE) Prions to InactivationPLOS Pathogens, 2008
- Use of containment pans and lids for autoclaving caustic solutionsAmerican Journal of Infection Control, 2003
- Observations on thermostable subpopulations of the unconventional agents that cause transmissible degenerative encephalopathiesVeterinary Microbiology, 1998
- Inactivation of the 22A strain of scrapie agent by autoclaving in sodium hydroxideVeterinary Microbiology, 1997
- DANGER OF ACCIDENTAL PERSON-TO-PERSON TRANSMISSION OF CREUTZFELDT-JAKOB DISEASE BY SURGERYThe Lancet, 1977