In-situ microscale through-silicon via strain measurements by synchrotron x-ray microdiffraction exploring the physics behind data interpretation
Authors:
- 15 September 2014
- journal article
- conference paper
- Published by AIP Publishing in Applied Physics Letters
- Vol. 105 (11) , 112109
Abstract
In-situ microscale thermomechanical strain measurements have been performed in combination with synchrotron x-ray microdiffraction to understand the fundamental cause of failures in microelectronics devices with through-silicon vias. The physics behind the raster scan and data analysis of the measured strain distribution maps is explored utilizing the energies of indexed reflections from the measured data and applying them for beam intensity analysis and effective penetration depth determination. Moreover, a statistical analysis is performed for the beam intensity and strain distributions along the beam penetration path to account for the factors affecting peak search and strain refinement procedure.Keywords
Funding Information
- Semiconductor Research Corporation (2012-KJ-2255)
This publication has 15 references indexed in Scilit:
- Thermomechanical strain measurements by synchrotron x-ray diffraction and data interpretation for through-silicon viasApplied Physics Letters, 2013
- Submicron mapping of strain distributions induced by three-dimensional through-silicon via featuresApplied Physics Letters, 2013
- Failure analysis of through-silicon vias in free-standing wafer under thermal-shock testMicroelectronics Reliability, 2013
- Micro-Raman spectroscopy and analysis of near-surface stresses in silicon around through-silicon vias for three-dimensional interconnectsJournal of Applied Physics, 2012
- Measurement of stresses in Cu and Si around through-silicon via by synchrotron X-ray microdiffraction for 3-dimensional integrated circuitsMicroelectronics Reliability, 2012
- Characterization of thermal stresses in through-silicon vias for three-dimensional interconnects by bending beam techniqueApplied Physics Letters, 2012
- A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light sourceReview of Scientific Instruments, 2009
- Three-dimensional silicon integrationIBM Journal of Research and Development, 2008
- Differential-aperture X-ray structural microscopy: a submicron-resolution three-dimensional probe of local microstructure and strainMicron, 2004