A Comparison of the Retention of Three Endodontic Dowel Systems Following Different Surface Treatments
- 17 December 2007
- journal article
- research article
- Published by Wiley in Journal of Prosthodontics
- Vol. 17 (4) , 269-273
Abstract
Purpose: Practitioners have several options during the selection of a dowel for core restoration, including metal and glass fiber materials. Retention of the cemented dowel is critical for the success of this type of restoration. The purpose of this in vitro study was to evaluate the effect of two surface treatments on the retention of three types of dowels placed into prepared canals with a resin cement. Materials and Methods: Following the removal of the clinical crown, gutta percha was used to restore canals prepared to size 40 in 90 extracted human anterior teeth. The access openings were then sealed, and the teeth stored in water for 3 weeks at 37°C. Post preparations were made to a depth of 9 mm, and parallel ParaPost, FibreKleer, and FibreKor dowels were each used to restore 30 teeth. Ten dowels in each group received no surface roughening treatment, 10 were air abraded with 50 μ aluminum oxide, and 10 were air abraded with CoJet. The specimens were stored in water for 24 hours at 37°C following dowel placement and prior to debonding with an Instron Testing Machine. Results: The forces (N) required in tensile load to dislodge the dowels for each group were: ParaPost/CoJet 214.04 ± 91.72, FibreKleer/AlOxide 196.07 ± 57.69, ParaPost/AlOxide 184.46 ± 35.05, FibreKleer/CoJet 176.36 ± 42.43, FibreKor/AlOxide 174.32 ± 53.64, ParaPost/Unroughened 174.14 ± 40.74, FibreKor/CoJet 167.16 ± 35.94, FibreKor/Unroughened 116.69 ± 37.01, and FibreKleer/Unroughened 96.88 ± 33.45. Post hoc analysis demonstrated that the unroughened FibreKor and FibreKleer dowels had significantly less retention than all other test groups (p≤ 0.05). Conclusion: Surface roughening with air abrasion increases retention in dowels cemented with a resin cement. Both the aluminum oxide and CoJet systems were equally effective in this regard.Keywords
This publication has 20 references indexed in Scilit:
- The adhesion between prefabricated FRC posts and composite resin cores: microtensile bond strength with and without post-silanizationDental Materials, 2005
- Effect of length and diameter of tapered posts on the retentionJournal of Oral Rehabilitation, 2002
- In vitro comparison of the fracture resistance and failure mode of fiber, ceramic, and conventional post systems at various stages of restorationJournal of Prosthodontics, 2001
- Evaluation of pre-fabricated root canal postsJournal of Oral Rehabilitation, 2001
- Carbon fiber post adhesion to resin luting cement in the restoration of endodontically treated teethJournal of Materials Science: Materials in Medicine, 2000
- Survival rate and failure characteristics for two post designsThe Journal of Prosthetic Dentistry, 1995
- Effects of sandblasting and silica-coating procedures on pure titaniumJournal of Dentistry, 1994
- Biological response to chopped‐carbon‐fiber‐reinforced peekJournal of Biomedical Materials Research, 1992
- Ferrule design and fracture resistance of endodontically treated teethThe Journal of Prosthetic Dentistry, 1990
- Retention of endodontic dowels: Effects of cement, dowel length, diameter, and designThe Journal of Prosthetic Dentistry, 1978