Radiation-free insertion of distal interlocking screw in tibial and femur nailing: A simple technique
Open Access
- 1 January 2012
- journal article
- surgical technique
- Published by CLOCKSS Archive in Journal of Surgical Technique and Case Report
- Vol. 4 (1) , 15-8
Abstract
Background: Distal interlocking screw insertion in intramedullary nailing of long-bone fracture is a challenging task for orthopedic surgeons. It is difficult particularly when the surgeon is in his learning stage or when image intensifier is not available. We describe a radiation-free technique of distal interlocking screw insertion which is easy and practicable. Materials and Methods: In this technique, a same length nail is placed over the skin (outer nail) and through its distal-most screw hole, a 3.2 mm drill bit is inserted to drill the distal locking screw hole of the intramedullary nail (inner nail). With a small skin incision over the distal screw holes, the distal-most screw hole is identified; the bone window overlying the screw hole is widened with an awl and a locking bolt is inserted with a washer under direct visualization. The other distal interlocking screw is simply drilled by matching the other three holes of the outer and inner nails. We have operated 86 patients (39 femoral shaft fracture and 47 tibial shaft fracture) in 1 year where this technique was used. There were 41 open fracture and 45 closed fracture. Results: Within 6 months of follow-up, bony union was achieved in 36 of 39 femur fractures and 45 of 47 tibial fractures. No unwanted complications were observed during the postoperative period and in follow-up. Conclusion: This method of radiation-free distal interlocking screw insertion is simple and can be used in third world country where image intensifier facility is not available. However, surgeons are encouraged to use image intensifier facility where the facility is available.Keywords
This publication has 19 references indexed in Scilit:
- Systematic review shows lowered risk of nonunion after reamed nailing in patients with closed tibial shaft fracturesInjury, 2010
- Prevalence of Cancer in Female Orthopaedic Surgeons in the United StatesJournal of Bone and Joint Surgery, 2010
- Dosimetry during intramedullary nailing of the tibiaActa Orthopaedica, 2009
- Nail over nail technique for distal locking of femoral intramedullary nailsInternational Orthopaedics, 2008
- Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implantsInjury, 2004
- Tibial intramedullary nail distal interlocking screw placement: comparison of the free-hand versus distally-based targeting device techniquesInjury, 2001
- Radiation Exposure to the Orthopaedic Surgical Team During Fluoroscopy: "How Far Away Is Far Enough?"Journal of Orthopaedic Trauma, 1997
- The deformation of small diameter solid tibial nails with unreamed intramedullary insertionJournal of Biomechanics, 1997
- A Simple Technique for Insertion of Distal Screws into Interlocking NailsJournal of Orthopaedic Trauma, 1995
- Locking nailing: an aid to distal targettingInjury, 1989