Delayed intraocular lens dislocation after neodymium:YAG capsulotomy
Authors:
- Hans HoeraufHHHans Hoerauf
- Johann RoiderJRJohann Roider
- Horst LaquaHLHorst Laqua
- 1 November 1998
- journal article
- case report
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 24 (11) , 1541-1543
Abstract
A poly(methyl methacrylate)(PMMA) intraocular lens (IOL) dislocated into the vitreous cavity in 2 patients after a neodymium:YAG (Nd:YAG) laser posterior capsulotomy. In Case 1, the capsulotomy was performed 19 months after extracapsular cataract extraction (ECCE) and sulcus fixation of an IOL. Six months later the IOL dislocated posteriorly. In Case 2, ECCE with intracapsular IOL implantation was followed 4 years later by an Nd:YAG capsulotomy; 6 months later the IOL dislocated into the vitreous cavity within the intact capsular bag. Different mechanisms were responsible for the dislocation: in case 1, radial tearing of the large capsular defect with IOL loosening and dislocation into the vitreous cavity; in Case 2, zonulysis and IOL dislocation within the intact capsular bag. A neodymium:YAG capsulotomy may cause delayed IOL dislocation into the vitreous cavity.Keywords
This publication has 19 references indexed in Scilit:
- Intraocular pressure change after neodymium:YAG capsulotomyJournal of Cataract & Refractive Surgery, 1997
- Cystoid Macular Edema, Retinal Detachment, and Glaucoma after Nd:YAG Laser Posterior CapsulotomyAmerican Journal of Ophthalmology, 1991
- Late-Onset Elevation in Intraocular Pressure After Neodymium-YAG Laser Posterior CapsulotomyArchives of Ophthalmology (1950), 1991
- Pars plana vitrectomy in the management of subluxed and posteriorly dislocated intraocular lensesGraefe's Archive for Clinical and Experimental Ophthalmology, 1987
- Review of the clinical literature on the use of the Nd:YAG laser for posterior capsulotomyJournal of Cataract & Refractive Surgery, 1986
- Long-term results of Nd:YAG laser posterior capsulotomy with the Swiss laserJournal of Cataract & Refractive Surgery, 1986
- Complications Associated with the Use of the Neodymium:YAG LaserOphthalmology, 1985
- Intermediate-Term Changes in Intraocular Pressure After Neodymium-YAG Laser Posterior CapsulotomyAmerican Journal of Ophthalmology, 1985
- Acute Elevations of Intraocular Pressure Following Nd:YAG Laser Posterior CapsulotomyOphthalmology, 1985
- Long-term follow-up of Nd:YAG laser posterior capsulotomyAmerican Intra-Ocular Implant Society Journal, 1984