Comparison of Autof ms1000 and Bruker Biotyper MALDI‐TOF MS Platforms for Routine Identification of Clinical Microorganisms
Open Access
- 1 January 2021
- journal article
- research article
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Abstract
Matrix‐assisted laser desorption ionization‐time of flight mass spectrometry (MALDI‐TOF MS) is widely used in clinical microbiology laboratories because it is cost‐effective, reliable, and fast. This study is aimed at comparing the identification performance of the recently developed Autof ms1000 (Autobio, China) with that of the Bruker Biotyper (Bruker Daltonics, Germany). From January to June 2020, 205 preserved strains and 302 clinical isolates were used for comparison. Bacteria were tested with duplicates of the direct transfer method, and formic acid extraction was performed if the results were not at the species level. Fungi were tested with formic acid extraction followed by ethanol extraction methods. 16S rRNA or ITS region sequence analysis was performed on isolates that could not be identified by any of the instruments and on isolates that showed inconsistent results. The time to result of each instrument was also compared. Among preserved strains, species‐level identification results were obtained in 202 (98.5%) strains by the Autof ms1000 and 200 (97.6%) strains by the Bruker Biotyper. Correct identification at the species/complex level was obtained for 200 (97.6%) strains by the Autof ms1000 and for 199 (97.1%) strains by the Bruker Biotyper. Among clinical isolates, species‐level identification results were obtained in 301 (99.7%) strains and 300 (99.3%) strains by the Autof ms1000 and Bruker Biotyper, respectively. Correct identification at the species/complex level was achieved for 299 (99.0%) strains by the Autof ms1000 and for 300 (99.3%) strains by the Bruker Biotyper. The time to analyze 96 spots was approximately 14 min for the Autof ms1000 and approximately 27 min for the Bruker Biotyper. The two instruments showed comparable performance for the routine identification of clinical microorganisms. In addition, the Autof ms1000 has a short test time, making it convenient for use in clinical microbiology laboratories.Keywords
Funding Information
- Bosung Scientific Co., Ltd
This publication has 31 references indexed in Scilit:
- Evaluation of a new matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry system for the identification of yeast isolationJournal of Clinical Laboratory Analysis, 2018
- Comparison of a New Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Platform, ASTA MicroIDSys, With Bruker Biotyper for Species IdentificationAnnals of Laboratory Medicine, 2017
- Head-to-head comparison of Microflex LT and Vitek MS systems for routine identification of microorganisms by MALDI-TOF mass spectrometry in ChilePLOS ONE, 2017
- Performances and Reliability of Bruker Microflex LT and VITEK MS MALDI-TOF Mass Spectrometry Systems for the Identification of Clinical MicroorganismsBioMed Research International, 2015
- A Side by Side Comparison of Bruker Biotyper and VITEK MS: Utility of MALDI-TOF MS Technology for Microorganism Identification in a Public Health Reference LaboratoryPLOS ONE, 2015
- MALDI-TOF MS for the Diagnosis of Infectious DiseasesClinical Chemistry, 2015
- Comparison of the Vitek MS and Bruker Microflex LT MALDI-TOF MS platforms for routine identification of commonly isolated bacteria and yeast in the clinical microbiology laboratoryDiagnostic Microbiology and Infectious Disease, 2015
- Real-time comparative evaluation of bioMerieux VITEK MS versus Bruker Microflex MS, two matrix-assisted laser desorption-ionization time-of-flight mass spectrometry systems, for identification of clinically significant bacteriaBMC Microbiology, 2014
- Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry: a Fundamental Shift in the Routine Practice of Clinical MicrobiologyClinical Microbiology Reviews, 2013
- Comparison of the Microflex LT and Vitek MS Systems for Routine Identification of Bacteria by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass SpectrometryJournal of Clinical Microbiology, 2012