An in vivo pilot study of a microporous thin film nitinol-covered stent to assess the effect of porosity and pore geometry on device interaction with the vessel wall
Authors:
- 8 December 2016
- journal article
- research article
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 31 (8) , 1196-1202
Abstract
Sputter-deposited thin film nitinol constructs with various micropatterns were fabricated to evaluate their effect on the vessel wall in vivo when used as a covering for commercially available stents. Thin film nitinol constructs were used to cover stents and deployed in non-diseased swine arteries. Swine were sacrificed after approximately four weeks and the thin film nitinol-covered stents were removed for histopathologic evaluation. Histopathology revealed differences in neointimal thickness that correlated with the thin film nitinol micropattern. Devices covered with thin film nitinol with a lateral × vertical length = 20 × 40 µm diamond pattern had minimal neointimal growth with well-organized cell architecture and little evidence of ongoing inflammation. Devices covered with thin film nitinol with smaller fenestrations exhibited a relatively thick neointimal layer with inflammation and larger fenestrations showed migration of inflammatory and smooth muscle cells through the micro fenestrations. This “proof-of-concept” study suggests that there may be an ideal thin film nitinol porosity and pore geometry to encourage endothelialization and incorporation of the device into the vessel wall. Future work will be needed to determine the optimal pore size and geometry to minimize neointimal proliferation and in-stent stenosis.Keywords
This publication has 34 references indexed in Scilit:
- TEM characterization of super-hydrophilic Ni–Ti thin filmMaterials Letters, 2011
- Coronary StentsJACC, 2010
- Nitinol Stent Implantation Versus Balloon Angioplasty for Lesions in the Superficial Femoral Artery and Proximal Popliteal ArteryCirculation: Cardiovascular Interventions, 2010
- Thin-film nitinol (NiTi): A feasibility study for a novel aortic stent graft materialJournal of Vascular Surgery, 2009
- Thin Film Nitinol Covered Stents: Design and Animal TestingASAIO Journal, 2008
- The Pathophysiology and Burden of RestenosisThe American Journal of Cardiology, 2007
- Biocorrosion investigation of two shape memory nickel based alloys: Ni‐Mn‐Ga and thin film NiTiJournal of Biomedical Materials Research Part A, 2007
- Value of the Hemobahn/Viabahn Endoprosthesis in the Treatment of Long Chronic Lesions of the Superficial Femoral Artery:6 Years of ExperienceJournal of Endovascular Therapy, 2006
- Pathobiologic Responses to Stenting 11Supported in part by grants from the National Institutes of Health (GM/HL49039 and HL03104), the Burroughs Wellcome Fund for Experimental Therapeutics, Durham, North Carolina, and the Whitaker Foundation, Rosslyn, Virginia.The American Journal of Cardiology, 1998
- Perspectives series: cell adhesion in vascular biology. Smooth muscle migration in atherosclerosis and restenosis.Journal of Clinical Investigation, 1997