High-Throughput Analysis of 25-OH-Vitamin D2 and D3 Using Multichannel Liquid Chromatography-Tandem Mass Spectrometry
- 21 September 2022
- book chapter
- Published by Springer Nature
- Vol. 2546, 523-537
Abstract
Liquid-chromatography tandem mass spectrometry (LC-MS/MS) has been shown to be an effective approach in the clinical analysis of 25-OH-vitamin D in patient serum. Test volumes vary among laboratories and different levels of throughput are required for different settings. LC-MS/MS assays with multiple LC channels can be beneficial for labs with the demand of large sample volume (e.g., 300 or more samples) to control costs and fulfill a reasonable turnaround time. We hereby present an assay that employs 4 LC channels (4-plex), which are coupled to the TSQ Endura triple-quadrupole (QqQ) MS instrument, for a high-throughput solution. Briefly, the pre- and postelution segments of the LC gradient are diverted to waste via solenoid valve controls, reserving the data acquisition for only the elution segment per injection per channel at a time. The multiplexing affords a manifold increase in throughput and the optimization of the duty cycle, without compromise in assay performance and precision. Key words 25-OH-vitamin D high-throughput LC-MS/MS multiplex HPLC atmospheric pressure chemical ionization (APCI) Multiple-reaction-monitoring (MRM) duty cycle LC-to-LC channel precisionKeywords
This publication has 9 references indexed in Scilit:
- Vitamin D Metabolism Varies among Women in Different Reproductive States Consuming the Same Intakes of Vitamin D and Related NutrientsThe Journal of Nutrition, 2016
- High-Throughput Serum 25-Hydroxy Vitamin D Testing with Automated Sample Preparation2016
- An assessment of 25-hydroxyvitamin D measurements in comparability studies conducted by the Vitamin D Metabolites Quality Assurance ProgramClinica Chimica Acta, 2013
- Total 25-Hydroxyvitamin D Determination by an Entry Level Triple Quadrupole Instrument: Comparison between Two Commercial KitsBioMed Research International, 2013
- Development and comparison of three liquid chromatography–atmospheric pressure chemical ionization/mass spectrometry methods for determining vitamin D metabolites in human serumJournal of Chromatography A, 2012
- State-of-the-Art Vitamin D Assays: A Comparison of Automated Immunoassays with Liquid Chromatography–Tandem Mass Spectrometry MethodsClinical Chemistry, 2012
- Misleading measures in Vitamin D analysis: A novel LC-MS/MS assay to account for epimers and isobarsNutrition Journal, 2011
- Metabolic profiling of major vitamin D metabolites using Diels–Alder derivatization and ultra-performance liquid chromatography–tandem mass spectrometryAnalytical and Bioanalytical Chemistry, 2008
- Circulating 25-Hydroxyvitamin D Levels Indicative of Vitamin D Sufficiency: Implications for Establishing a New Effective Dietary Intake Recommendation for Vitamin DThe Journal of Nutrition, 2005