Imagent Improves Endocardial Border Delineation, Inter-reader Agreement, and the Accuracy of Segmental Wall Motion Assessment
Authors:
- 1 February 2003
- journal article
- clinical trial
- Published by Wiley in Echocardiography
- Vol. 20 (2) , 151-161
Abstract
This study was conducted to assess the ability of a new echocardiographic contrast agent, Imagent (perflexane lipid microspheres; Alliance Pharmaceutical Corp., San Diego, CA), to improve endocardial border delineation (EBD) and assessment of segmental wall motion (SWM). This was achieved by analysis of inter-reader agreement by echocardiography and comparison with an independent imaging technique, magnetic resonance imaging (MRI). Two separate, independent, prospective, randomized, controlled, multicenter trials were conducted at 26 centers and included a total of 409 efficacy-evaluable patients. In Study A 206 patients were randomized to receive either Imagent or saline and in Study B, 203 patients received Imagent with a subset imaged by both echocardiography and MRI. All patients were required to have suboptimal baseline images using fundamental imaging. Images were optimized at baseline prior to contrast and the settings maintained post-contrast. Imagent, a suspension of perfluorohexane-filled spheres with flexible lipid shells, was administered as an IV bolus at 0.125 mg/kg body weight. Gated MRI studies were performed within 48 hours of dosing in a subset of 26 subjects. Six expert independent blinded readers reviewed unpaired noncontrast and contrast exams and scored EBD and SWM. Analysis of inter-reader agreement was performed by comparing the SWM score (1 to 5) recorded by each reader pair. In addition, unanimity between readers for SWM was evaluated. For comparison to MRI, the results from echo readers 4, 5, and 6 were each compared with a single independent MRI reader. The patients enrolled in these clinical trials displayed markedly suboptimal images with 49% and 71% (Study A and Study B) of the segments determined by the readers to be suboptimal prior to contrast administration. All readers recorded statistically significant (P < 0.0001) improvement in total EBD scores following the administration of Imagent. Comparison of noncontrast SWM scores for each pair of echo readers resulted in agreement in an average of 39%, of segments in Study A, and 31% of the segments in Study B. Use of Imagent improved agreement in SWM scores to 65% in Study A, and 48% of segments in Study B (P < 0.0001) for all reader pairs in both studies. Reader unanimity in SWM scores increased from 13% to 41% of the segments with the administration of Imagent. Blinded review of the noncontrast echo examinations resulted in agreement with MRI derived SWM scores in 15% of the segments. The administration of Imagent improved this agreement to 47%, of the segments (P < pr = 0.0005 for each blinded reader). Use of Imagent during echocardiographic imaging improves EBD, providing a significant improvement in inter-reader agreement in SWM evaluation with echo and greater than a threefold improvement in SWM scoring accuracy with MRI.Keywords
This publication has 14 references indexed in Scilit:
- Contrast dobutamine stress echocardiography: Clinical practice assessment in 300 consecutive patientsJournal of the American Society of Echocardiography, 2001
- Effect of contrast enhancement on transthoracic echocardiographic assessment of left ventricular regional wall motionThe American Journal of Cardiology, 1999
- What Determines Echogenicity in a General Population? The Tromsø StudyJournal of the American Society of Echocardiography, 1999
- Use of harmonic imaging without echocardiographic contrast to improve two-dimensional image qualityThe American Journal of Cardiology, 1998
- ACC/AHA Guidelines for the Clinical Application of EchocardiographyCirculation, 1997
- Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiogramsJACC, 1996
- Recommendations for Quantitation of the Left Ventricle by Two-Dimensional EchocardiographyJournal of the American Society of Echocardiography, 1989
- Guidelines for Optimal Physician Training in EchocardiographyJournal of the American Society of Echocardiography, 1988
- Regional left ventricular wall motion assessment: Comparison of two-dimensional echocardiography and radionuclide angiography with contrast angiography in healed myocardial infarctionThe American Journal of Cardiology, 1985
- “Mini-mental state”Journal of Psychiatric Research, 1975