Grid voltage sensor fault‐tolerant control for single‐phase two‐level PWM rectifier
Open Access
- 22 June 2021
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 16 (7) , 776-788
Abstract
The main purpose of this work is to address the problem of robust grid voltage sensor fault‐tolerant control for a single‐phase two‐level rectifier. First, considering a rectifier with disturbances and grid voltage sensor fault, the standard switched system model is constructed. Based on identical transformation, the original system is converted into an augmented system. In the augmented system, the information of the grid voltage sensor fault is included in the state vector. Second, an unknown input observer is designed for the augmented system for sensor fault estimation. The observer error is totally robust against independent deterministic disturbances. In addition, the effect of the disturbance caused by unknown disturbances or a modelling error is minimised with respect to a prescribed H ∞ performance index. Finally, the sensor fault‐tolerant control is realised by fault compensation technique, which protects the rectifier from serious performance degradation in the presence of the grid voltage sensor fault. The proposed fault‐tolerant control strategy requires no supplementary hardware and all the inputs involved in the algorithm are directly available. Simulation and experimental results are exhibited to illustrate the capability of the proposed method to tolerate the grid voltage sensor fault.Keywords
Funding Information
- National Natural Science Foundation of China (61733015, 61773323, U1934221)
- Science and Technology Department of Sichuan Province (2020YFQ0057, 2021JDJQ0012)
This publication has 28 references indexed in Scilit:
- Open-circuit fault diagnosis and voltage sensor fault tolerant control of a single phase pulsed width modulated rectifierMathematics and Computers in Simulation, 2017
- Deadbeat Predictive Power Control of Single-Phase Three-Level Neutral-Point-Clamped Converters Using Space-Vector Modulation for Electric Railway TractionIEEE Transactions on Power Electronics, 2015
- Real-Time IGBT Open-Circuit Fault Diagnosis in Three-Level Neutral-Point-Clamped Voltage-Source Rectifiers Based on Instant Voltage ErrorIEEE Transactions on Industrial Electronics, 2014
- Fault tolerant control allocation using unknown input observersAutomatica, 2014
- Robust actuator multiplicative fault estimation with unknown input decoupling for a wind turbine system2013
- Robust fault reconstruction for linear parameter varying systems using sliding mode observersInternational Journal of Robust and Nonlinear Control, 2013
- Observer-based fault-tolerant control for a class of switched nonlinear systemsIET Control Theory & Applications, 2007
- Design of unknown input observers and robust fault detection filtersInternational Journal of Control, 1996
- Electric railway traction. Part 2: Traction drives with three-phase induction motorsPower Engineering Journal, 1994
- AC/DC/AC high voltage traction drives with quasi-zero reactive power demandIEEE Transactions on Power Electronics, 1993