Monitoring haemodynamic response to fluid-challenge in ICU
- 1 February 2019
- journal article
- research article
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 36 (2) , 135-143
Abstract
The ability of the pressure recording analytical method (PRAM) in tracking change in cardiac output (ΔCO) after a fluid challenge in ICU needs to be evaluated with the most contemporary comparison methods recommended by experts. Our objective was to report the trending ability of PRAM in tracking ΔCO after a fluid challenge in ICU and to compare this with oesophageal Doppler monitoring (ODM). Prospective, observational study. Hôpital Lariboisière and Hôpital Européen George Pompidou, Paris, France, from April 2016 to December 2017. Critically ill patients admitted to ICU with monitoring of CO monitored by ODM and invasive arterial pressure. ΔCO after fluid challenge was simultaneously registered with ODM and PRAM connected to the arterial line. Polar statistics (mean angular bias, radial limits of agreement and polar concordance rate) and clinical concordance evaluation (error grid and clinical concordance rate). Predictors of bias were determined. Sixty-eight fluid challenge were administered in 49 patients. At the time of fluid challenge, almost all were mechanically ventilated (99%), with 85% receiving norepinephrine. Admission diagnosis was septic shock in 70% of patients. Patients had a Sequential Organ Failure Assessment score of 10 [7 to 12] and a median Simplified Acute Physiology Score II of 61 [49 to 69]. Relative ΔCO bias was 7.8 (6.3°) with radial limits of agreement of ±41.7°, polar concordance rate 80% and clinical concordance rate 74%. ΔCO bias was associated with baseline bias (P = 0.007). Baseline bias was associated with radial location of the arterial line (P = 0.03). When compared with ODM, PRAM has insufficient performance to track ΔCO induced by fluid challenge in ICU patients. Baseline bias is an independent predictor of trending bias. IRB 00010254-2016-033.Keywords
This publication has 29 references indexed in Scilit:
- Focus on fluid therapyIntensive Care Medicine, 2017
- Comparison Between Doppler-Echocardiography and Uncalibrated Pulse Contour Method for Cardiac Output Measurement: A Multicenter Observational Study*Critical Care Medicine, 2016
- Methodology of method comparison studies evaluating the validity of cardiac output monitors: a stepwise approach and checklistBritish Journal of Anaesthesia, 2016
- Tracking Changes in Cardiac OutputAnesthesia & Analgesia, 2015
- Fluid challenges in intensive care: the FENICE studyIntensive Care Medicine, 2015
- Volume expansion in the first 4 days of shock: a prospective multicentre study in 19 French intensive care unitsIntensive Care Medicine, 2014
- Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care MedicineIntensive Care Medicine, 2014
- Evaluation of stroke volume variations obtained with the pressure recording analytic method*Critical Care Medicine, 2012
- Cardiac Index Assessment by the Pressure Recording Analytic Method in Unstable Patients With Atrial FibrillationJournal of Cardiothoracic and Vascular Anesthesia, 2011
- Assessment of cardiac output from systemic arterial pressure in humansCritical Care Medicine, 2002