Research on vacuum insulation properties — In situ measurements and surface analysis
Author:
- 21 November 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 1-8
Abstract
Ion beam sputter cleaning, electrode surface heating by an infrared-ray, and an X-ray Photoelectron Spectroscopy (XPS) system were equipped in conjunction with a vacuum breakdown measurement apparatus (in situ experiment system). This system enables to carry out surface treatments, surface analysis and breakdown characteristics measurements without exposure of sample electrodes to air. It was confirmed that in situ surface cleaning was effective and necessary to achieve higher conditioned breakdown field. However, also confirmed was that the breakdown field after the in situ cleaning did not always improve breakdown field at the first voltage application. Conditioning was carried out by repetitive breakdowns by applying impulse voltage application. Surface analysis revealed that electrode surface before the conditioning was covered with oxidized layer and hydro-carbon contaminated layer and those layers were completely removed after the conditioning. Electrode heating was able to get clean surface and achieve higher conditioned field. Many experimental results obtained from in situ system represent that precautions of electrode surface were necessary but was not sufficient, and strongly suggest there may be factors to be found out.Keywords
This publication has 7 references indexed in Scilit:
- Influence of vacuum heat treatment to the breakdown characteristic and the field electron emission characteristic of oxygen-free copper electrodes after spark conditioning2006
- Parameters influencing breakdown characteristics of vacuum gaps during spark conditioningIEEE Transactions on Dielectrics and Electrical Insulation, 1999
- Recent experiments on vacuum breakdown of oxygen-free copper electrodesIEEE Transactions on Dielectrics and Electrical Insulation, 1997
- Effect of Charge Carriers on the Prebreakdown Current Flowing Through a Parallel-Plate Vacuum GapIEEE Transactions on Electrical Insulation, 1982
- Investigation of Vacuum Breakdown Using Auger SpectroscopyJapanese Journal of Applied Physics, 1974
- Initiation of Electrical Breakdown in Ultrahigh VacuumJournal of Vacuum Science and Technology, 1964
- The Field Emission Initiated Vacuum Arc. I. Experiments on Arc InitiationPhysical Review B, 1953