Methodology for the Physical Validation and Optimal Sizing of Photovoltaic Generation Systems to Estimate Firm Energy for the Reliability Charge (ENFICC)
Preprint
- 20 July 2026
- preprint
- Published by MDPI AG in Preprints.org
Abstract
The integration of photovoltaic (PV) generation into power systems requires design methods that evaluate not only annual energy yield or installed capacity, but also the dependable contribution of the plant under critical supply conditions. This paper presents a prototype-driven methodology for the physical validation and optimal sizing of a grid-connected PV generation system aimed at estimating, auditing, and evaluating ENFICC-oriented photovoltaic sizing alternatives under the Colombian reliability framework. The workflow integrates three input databases: a ten-year hourly meteorological database from NASA POWER for 2016--2025, a filtered and expanded PV module catalog based on the CEC database, and a filtered and expanded inverter catalog based on the Sandia database. These inputs feed a sequential modeling chain that estimates clearness index, irradiance decomposition, plane-of-array irradiance, cell temperature, DC power, AC power, monthly equivalent daily energy, net effective capacity, regulatory upper bound, and final ENFICC. The methodology was first validated using the installed PV system in La Tebaida, Colombia, as a local physical reference. For the validation case, the model used 252 Jinko Tiger Neo JKM625N-78HL4-BDV modules, two Solis 60K-LV-5G inverters, 157.5 kWp DC, 120 kW AC, fixed topology, and an hourly local validation dataset derived from the installed system. The NASA-based physical validation produced a critical-month energy of 548.5~kWh/day and a final ENFICC of 438.8~kWh/day after applying the secondary-data factor $f_{\mathrm{sec}}=0.8$. After applying the corrected physical filters and monthly coverage checks to the NASA POWER physical irradiance series, ten independent GA runs produced final ENFICC values between 283.5 and 384.2 kWh/day, with a mean of 349.7 kWh/day. The fitness function in all GA runs was evaluated using the corrected NASA POWER physical irradiance series, not an alternative irradiance series. These corrected results do not support the previously inflated optimization values; instead, they show that the local physical validation stage is essential before interpreting GA outputs. The proposed methodology contributes to clean-energy planning by linking renewable-energy integration, physical validation, reproducible computation, and regulatory firm-energy estimation within a single engineering workflow.
Keywords
All Related Versions
- Version 1, 2026-07-20, Preprints
- Published version: Clean Technologies, 8 (5), 168.
This publication has 14 references indexed in Scilit:
- On–off-Grid Optimal Hybrid Renewable Energy Systems for House Units in IraqClean Technologies, 2024
- Optimizing Renewable Energy Integration through Innovative Hybrid Microgrid Design: A Case Study of Najran Secondary Industrial Institute in Saudi ArabiaClean Technologies, 2024
- Optimization of a Hybrid Solar PV and Gas Turbine Generator System Using the Loss of Load Probability IndexClean Technologies, 2020
- Modeling, size optimization and sensitivity analysis of a remote hybrid renewable energy systemEnergy, 2018
- Control principles of micro-source inverters used in microgridProtection and Control of Modern Power Systems, 2016
- Control techniques for three-phase four-leg voltage source inverters in autonomous microgrids: A reviewRenewable and Sustainable Energy Reviews, 2016
- A review of photovoltaic systems size optimization techniquesRenewable and Sustainable Energy Reviews, 2013
- Optimum design of hybrid renewable energy systems: Overview of different approachesRenewable and Sustainable Energy Reviews, 2012
- Simulation and optimization of stand-alone hybrid renewable energy systemsRenewable and Sustainable Energy Reviews, 2009
- Estimation of the diffuse radiation fraction for hourly, daily and monthly-average global radiationSolar Energy, 1982