Determination of organophosphorus fire retardants and plasticizers in wastewater samples using MAE-SPME with GC-ICPMS and GC-TOFMS detection
- 27 September 2007
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Environmental Monitoring
- Vol. 9 (12) , 1329-1336
Abstract
Determination of organophosphorus fire retardants and plasticizers at trace levels in wastewater is described. In this work, microwave assisted extraction (MAE) and solid-phase microextraction (SPME) are used for sample preparation to extract and preconcentrate the analytes, followed by analysis by gas chromatography coupled to inductively coupled plasma mass spectrometry (GC-ICP-MS) for phosphorus-specific detection. Gas chromatography coupled to time of flight mass spectrometry (GC-TOF-MS) was used to confirm the organphosphorus fire retardants in wastewater. The detection limits of organophosphorus fire retardants (OPFRs) were 29 ng L−1 for tri-n-butyl phosphate (TnBP), 45 ng for L−1 for tris(2-butoxyethyl)phosphate (TBEP), and 50 ng L−1 for tris(2-ethylhexyl)phosphate (TEHP). Optimized extraction conditions were performed at 65 °C for 30 min and with 10% NaCl. Application of MAE during the sample preparation prior to the SPME allowed the detection of tris(2-ethylhexyl) phosphate, which has been difficult to determine in previous work. Application of the method to wastewater samples resulted in detecting 3.1 μg L−1 P from TnBP, 5.0 μg L−1 P from TBEP, and 4.0 μg L−1 P from TEHP. The presence of these compounds were also confirmed by SPME-GC-TOF-MS.Keywords
This publication has 32 references indexed in Scilit:
- Organophosphate triesters in indoor environmentsJournal of Environmental Monitoring, 2005
- Determination of organophosphorus pesticides in spiked river water samples using solid phase microextraction coupled to gas chromatography with EI-MS and ICP-MS detectionJournal of Analytical Atomic Spectrometry, 2005
- Organophosphorus flame retardants and plasticizers in air from various indoor environmentsJournal of Environmental Monitoring, 2005
- Liquid Chromatography−Tandem Mass Spectrometry Determination of Nonionic Organophosphorus Flame Retardants and Plasticizers in Wastewater SamplesAnalytical Chemistry, 2005
- Indoor air sampling of organophosphate triesters using solid phase extraction (SPE) adsorbentsJournal of Environmental Monitoring, 2005
- Dynamic field sampling of airborne organophosphate triesters using solid-phase microextraction under equilibrium and non-equilibrium conditionsThe Analyst, 2004
- Organophosphorus flame retardants and plasticisers in surface watersScience of The Total Environment, 2004
- Plasticizer metabolites in the environmentWater Research, 2004
- Simultaneous determination of phosphate esters and phthalate esters in clean room air and indoor air by gas chromatography–mass spectrometryAnalytica Chimica Acta, 2004
- Determination of organophosphate ester plasticisers in blood donor plasma using a new stir‐bar assisted microporous membrane liquid‐liquid extractorJournal of Separation Science, 2003