Normality and Correlation Coefficient in Estimation of Insulators’ Spectral Signature
Authors:
- 12 January 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Letters
- Vol. 22 (8) , 1175-1179
Abstract
This work aims to classify the contamination state in insulators using statistical signal processing approaches. When subjected to high voltage, insulators can radiate radio frequency signals (corona effect). The histograms, normality, and correlation coefficient statistical methods are used to estimate the pollution state in glass insulators when subjected to 8 kV. It is shown that in particular situations the histograms can be used to distinguish clean and dirty insulators. The histogram limitation analysis can be improved using the correlation coefficient and the normality or Gaussianity test. Indeed, it is shown that using these parameters into an analysis per sub-bands, it is possible to estimate the pollution state of the insulators. That is, the analysis using these tools checks if the insulators spectra under test are noticeably different from the clean one, used as reference. It is achieved eliminating the fast variation of the correlation coefficient based on the amplitude and width of the peaks. The tests were done up to the frequency of 1 GHz using measured data.Keywords
This publication has 19 references indexed in Scilit:
- Influence of sugar as a contaminant on outdoor insulation characteristics of insulators in a substationIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Stage pre-warning based on leakage current characteristics before contamination flashover of porcelain and glass insulatorsIET Generation, Transmission & Distribution, 2009
- The Correlation Coefficient: An OverviewCritical Reviews in Analytical Chemistry, 2006
- Radiometric Location of Partial Discharge Sources on Energized High-Voltage PlantIEEE Transactions on Power Delivery, 2005
- Development of a new apparatus for contamination measurement of overhead transmission line insulatorsIEEE Transactions on Power Delivery, 1998
- Optical monitor for contamination on HV insulator surfacesIEEE Transactions on Dielectrics and Electrical Insulation, 1997
- Remark AS R94: A Remark on Algorithm AS 181: The W-test for NormalityJournal of the Royal Statistical Society Series C: Applied Statistics, 1995
- Interpretation of the Correlation Coefficient: A Basic ReviewJournal of Diagnostic Medical Sonography, 1990
- Estimation of source motion from time delay and time compression measurementsThe Journal of the Acoustical Society of America, 1980
- A Comparative Study of Various Tests for NormalityJournal of the American Statistical Association, 1968