Contact mechanics of metal-on-metal hip implants employing a metallic cup with a UHMWPE backing
Authors:
- 1 March 2003
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 217 (3) , 207-213
Abstract
The contact mechanics in metal-on-metal hip implants employing a cobalt chromium acetabular cup with an ultra-high molecular weight polyethylene (UHMWPE) backing were analysed in the present study using the finite element method. A general modelling methodology was developed to examine the effects of the interfacial boundary conditions between the UHMWPE backing and a titanium shell for cementless fixation, the coefficient of friction and the loading angle on the predicted contact pressure distribution at the articulating surfaces. It was found that the contact mechanics at the bearing surfaces were significantly affected by the UHMWPE backing. Consequently, a relatively constant pressure distribution was predicted within the contact conjunction, and the maximum contact pressure occurred towards the edge of the contact. On the other hand, the interfacial boundary condition between the UHMWPE backing and the titanium shell, the coefficient of friction and the loading angle were found to have a negligible effect on the contact mechanics at the bearing surfaces. Overall, the magnitude of the contact pressure was significantly reduced, compared with a similar cup without the UHMWPE backing. The importance of the UHMWPE backing on the tribological performance of metal-on-metal hip implants is discussed.Keywords
This publication has 18 references indexed in Scilit:
- Contact mechanics of a novel metal-on-metal total hip replacementProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001
- The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacementsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001
- In vitro comparison of the two hard-hard articulations for total hip replacementsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001
- Wear and Lubrication of Metal-on-Metal Hip ImplantsClinical Orthopaedics and Related Research, 1999
- Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulusProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1997
- In Vivo Wear of 3 Types of Metal on Metal Hip Prostheses During 2 Decades of UseClinical Orthopaedics and Related Research, 1996
- Metal on Metal Bearings in Hip ArthroplastyClinical Orthopaedics and Related Research, 1996
- A parametric analysis of the contact stress in ultra-high molecular weight polyethylene acetabular cupsMedical Engineering & Physics, 1994
- The Effect of Conformity and Plastic Thickness on Contact Stresses in Metal-Backed Plastic ImplantsJournal of Biomechanical Engineering, 1985
- The tribology (friction, lubrication and wear) of all-metal artificial hip jointsWear, 1971