Monitoring Active Patient Participation During Robotic Rehabilitation: Comparison Between a Robot-Based Metric and an EMG-Based Metric
Open Access
- 16 October 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 4156-4166
Abstract
While rehabilitation robots present a much-needed solution to improving early mobilization therapy in demanding clinical settings, they also present new challenges and opportunities in patient monitoring. Aside from the fundamental challenge of quantifying a patient’s voluntary contribution during robot-led therapy motion, many sensors cannot be used in clinical settings due to time and space limitations. In this paper, we present and compare two metrics for monitoring a patient’s active participation in the motion. The two metrics, each derived from first principles, have the same biomechanical interpretability, i.e., active work by the patient during the robotic mobilization therapy, but are calculated in two different spaces (Cartesian vs. muscle space). Furthermore, the sensors used to quantify these two metrics are fully independent from each other and the associated measurements are unrelated. Specifically, the robot-based work metric utilizes robot-integrated force sensors, while the EMG-based work metric requires electrophysiological sensors. We then apply the two metrics to therapy performed using a clinically certified, commercially available robotic system and compare them against the specific instructions given to the healthy subjects as well as against each other. Both metric outputs qualitatively match the expected behavior of the healthy subjects. Additionally, strong correlations (median R 2 > 0.80) are shown between the two metrics, not only for healthy subjects (n = 12) but also for patients (n = 2), providing solid evidence for their validity and translatability. Importantly, the robot-based work metric does not rely on any sensors outside of those integrated into the robot, thus making it ideal for application in clinical settings.Keywords
Funding Information
- Federal Ministry of Education and Research of the Federal Republic of Germany (BMBF) as part of the project Mobilisation Intensiv-Pflegebedrftiger durch adaptive Robotik (16SV7987)
- project Artificial Intelligence for Neuro Deficits (16ME0539K)
- Bavarian Ministry of Economic Affairs, Regional Development and Energy (StMWi Bayern) as part of the Lighthouse Initiative Geriatronics Project X (IUK-1807-0007//IUK582/001)
This publication has 47 references indexed in Scilit:
- Restoring Voluntary Control of Locomotion after Paralyzing Spinal Cord InjuryScience, 2012
- Long-term complications of critical careCritical Care Medicine, 2011
- Controlling patient participation during robot-assisted gait trainingJournal of NeuroEngineering and Rehabilitation, 2011
- Methodological aspects of SEMG recordings for force estimation – A tutorial and reviewJournal of Electromyography and Kinesiology, 2010
- Review of control strategies for robotic movement training after neurologic injuryJournal of NeuroEngineering and Rehabilitation, 2009
- The relationships between muscle, external, internal and joint mechanical work during normal walkingJournal of Experimental Biology, 2009
- Surface electromyography and muscle force: Limits in sEMG–force relationship and new approaches for applicationsClinical Biomechanics, 2009
- Computerized Visual Feedback: An Adjunct to Robotic-Assisted Gait TrainingPhysical Therapy, 2008
- Safety Issues That Should Be Considered When Mobilizing Critically Ill PatientsCritical Care Clinics, 2007
- Persistent neuromuscular and neurophysiologic abnormalities in long-term survivors of prolonged critical illness*Critical Care Medicine, 2003