Quality assurance practices in tuberculosis diagnostic health facilities in Ethiopia
Open Access
- 9 June 2022
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (6) , e0269601
Abstract
Introduction: The quality of tuberculosis laboratory services in health facilities is a mandatory component of detecting active pulmonary TB cases and treatment follow-up. However, ensuring the quality of laboratory test results is a concern. This study aimed to assess the quality assurance practices in the tuberculosis diagnostic health facilities of Ethiopia. Materials and methods: A cross-sectional study was conducted from October 2018 to March 2019 at nine governmental TB-culture laboratories and 34 randomly selected GeneXpert® MTB/RIF (Xpert® MTB/RIF) testing health facilities in Ethiopia. Participating health facilities were interviewed and laboratory documents and records present since 2017 were observed. Prior to the data collection, training was given to the data collectors. Descriptive statistics were used to produce results and were presented with tables and graphs. Results: From a total of 34 Xpert® MTB/RIF testing laboratories, 50% run Internal Quality Control (IQC) for Acid-Fast Bacillus (AFB) Microscopy and 67.6% had lot-to-lot verification of staining reagents. For the Xpert® MTB/RIF assay, a lot-to-lot verification of cartridge and method validation was performed only in 8.8%and 20.6% of Xpert® MTB/RIF testing laboratories respectively. All TB-culture laboratories included in the study ran negative control (start and end IQC) during TB-culture sample processing and performed lot-to-lot verification for Mycobacteria Growth Indicator Tube (MGIT) in 88.9% of TB-culture laboratories. External Quality Assessment (EQA) Proficiency Testing (PT) for AFB microscopy is practiced in 79.4% Xpert® MTB/RIF testing laboratories and 100.0% for the Xpert® MTB/RIF assay. TB-Culture PT participation practice among TB-culture laboratories was 88.9%. A major challenge for health facilities during PT participation was the AFB PT-sample transportation delay (40.7%) and the Xpert® MTB/RIF assay EQA-PT feedback missing (38.2%). Conclusion: This assessment reveals that IQC for AFB microscopy, lot-to-lot verification, method validation, and equipment calibration were not well-practiced. The majority of TB diagnostic health facility laboratories had EQA-PT participation practice, but a significant gap in PT-sample transportation and missing feedback was identified.Keywords
This publication has 24 references indexed in Scilit:
- Evidence from 617 laboratories in 47 countries for SLMTA-driven improvement in quality management systemsAfrican Journal of Laboratory Medicine, 2014
- Working toward a sustainable laboratory quality improvement programme through country ownership: Mozambique’s SLMTA storyAfrican Journal of Laboratory Medicine, 2014
- Weighing the costs: Implementing the SLMTA programme in Zimbabwe using internal versus external facilitatorsAfrican Journal of Laboratory Medicine, 2014
- Laboratory system strengthening and quality improvement in EthiopiaAfrican Journal of Laboratory Medicine, 2014
- Attaining ISO 15189 accreditation through SLMTA: A journey by Kenya’s National HIV Reference LaboratoryAfrican Journal of Laboratory Medicine, 2014
- Translating a National Laboratory Strategic Plan into action through SLMTA in a district hospital laboratory in BotswanaAfrican Journal of Laboratory Medicine, 2014
- One laboratory’s progress toward accreditation in TanzaniaAfrican Journal of Laboratory Medicine, 2014
- Training-of-trainers: A strategy to build country capacity for SLMTA expansion and sustainabilityAfrican Journal of Laboratory Medicine, 2014
- First Evaluation after Implementation of a Quality Control System for the Second Line Drug Susceptibility Testing of Mycobacterium tuberculosis Joint Efforts in Low and High Incidence CountriesPLOS ONE, 2013
- Strengthening Laboratory Management Towards Accreditation: The Lesotho experienceAfrican Journal of Laboratory Medicine, 2011