State-of-the-art magnetic resonance imaging sequences for pediatric body imaging
- 18 October 2022
- journal article
- research article
- Published by Springer Nature in Pediatric Radiology
- Vol. 53 (7) , 1285-1299
Abstract
Longer examination time, need for anesthesia in smaller children and the inability of most children to hold their breath are major limitations of MRI in pediatric body imaging. Fortunately, with technical advances, many new and upcoming MRI sequences are overcoming these limitations. Advances in data acquisition and k-space sampling methods have enabled sequences with improved temporal and spatial resolution, and minimal artifacts. Sequences to minimize movement artifacts mainly utilize radial k-space filling, and examples include the stack-of-stars method for T1-weighted imaging and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER)/BLADE method for T2-weighted imaging. Similarly, the sequences with improved temporal resolution and the ability to obtain multiple phases in a single breath-hold in dynamic imaging mainly use some form of partial k-space filling method. New sequences use a variable combination of data sampling methods like compressed sensing, golden-angle radial k-space filling, parallel imaging and partial k-space filling to achieve free-breathing, faster sequences that could be useful for pediatric abdominal and thoracic imaging. Simultaneous multi-slice method has improved diffusion-weighted imaging (DWI) with reduction in scan time and artifacts. In this review, we provide an overview of data sampling methods like parallel imaging, compressed sensing, radial k-space sampling, partial k-space sampling and simultaneous multi-slice. This is followed by newer available and upcoming sequences for T1-, T2- and DWI based on these other advances. We also discuss the Dixon method and newer approaches to reducing metal artifacts.Keywords
This publication has 61 references indexed in Scilit:
- SENSE with improved tolerance to inaccuracies in coil sensitivity mapsMagnetic Resonance in Medicine, 2012
- MR imaging near metal with undersampled 3D radial UTE‐MAVRIC sequencesMagnetic Resonance in Medicine, 2012
- DIfferential subsampling with cartesian ordering (DISCO): A high spatio‐temporal resolution dixon imaging sequence for multiphasic contrast enhanced abdominal imagingJournal of Magnetic Resonance Imaging, 2012
- Dixon techniques for water and fat imagingJournal of Magnetic Resonance Imaging, 2008
- Effects of refocusing flip angle modulation and view ordering in 3D fast spin echoMagnetic Resonance in Medicine, 2008
- Parallel magnetic resonance imagingPhysics in Medicine & Biology, 2007
- T2‐weighted spine imaging with a fast three‐point dixon technique: Comparison with chemical shift selective fat suppressionJournal of Magnetic Resonance Imaging, 2004
- Breath‐hold water and fat imaging using a dual‐echo two‐point dixon technique with an efficient and robust phase‐correction algorithmMagnetic Resonance in Medicine, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999