Improved analysis of the time domain response of scanning force microscope cantilevers
Authors:
- 15 December 2000
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 88 (12) , 7321-7327
Abstract
The snap-to-contact instability encountered in scanning force microscopy-force spectroscopy (SFMFS) limits the range of forces measurable in SFM force–distance experiments. We have generalized the flexural beam theory for SFM cantilevers to include tip interactions that are present in the snap-to-contact region. We compare solutions for the beam theory with the simple harmonic oscillator (SHO) that is often used to approximate SFM cantilevers. The limitations of the SHO model are encountered when large force gradients are present. This causes the beam shape to change leading to error when the SHO is used to reconstruct force curves collected in the snap-to-contact region. We quantify the error introduced into a force–separation curve reconstructed using the SHO approximation by numerical simulation. The force–separation curve reconstructed by the SHO was significantly inaccurate and had distorted separation dependence. This makes physical interpretation of force curves reconstructed using the SHO approximation tenuous when force microscope data from the snap-to-contact region is used.Keywords
This publication has 26 references indexed in Scilit:
- Improved Algorithm to Extract Force-distance Curves from Scanning Force Microscope DataMRS Proceedings, 1999
- New Method for Noncontact Atomic Force Microscopy Image SimulationsJapanese Journal of Applied Physics, 1999
- Tip-sample interactions in scanning force microscopy using the frequency-modulation technique: Experiments and computer simulationEurophysics Letters, 1998
- Nature of Tip-Sample Interaction in Dynamic Mode Atomic Force MicroscopyJapanese Journal of Applied Physics, 1997
- An historical review of surface force measurement techniquesColloids and Surfaces A: Physicochemical and Engineering Aspects, 1997
- Precise force curve detection system with a cantilever controlled by magnetic force feedbackReview of Scientific Instruments, 1997
- Tip-sample interactions in scanning force microscopy using the frequency-modulation technique: Experiments and computer simulationEurophysics Letters, 1997
- Near-surface tricritical behavior of at the - phase transitionPhysical Review B, 1997
- Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivityJournal of Applied Physics, 1991
- Atomic force microscope–force mapping and profiling on a sub 100-Å scaleJournal of Applied Physics, 1987