Inverter-Based Local AC Bus Voltage Control Utilizing Two DOF Control
Authors:
- 2 May 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 23 (3) , 1288-1298
Abstract
Small- and medium-sized distributed generation (DG) systems in a microgrid normally have inverters, and the inverter outputs are connected to the grid through an LCL filter. In this paper, we are interested in designing a DG inverter that behaves like a uninterruptible power supply (UPS) for its dedicated loads, while enabling power flow control with the microgrid. If the grid power is lost, then the DG system can be transferred smoothly to the island (stand-alone) operation. This islanding capability provides a higher reliability of the local ac bus than the conventional power system. In order to have such a UPS functionality, the inverter is desired to have a high control bandwidth, which is required for regulating the ac bus voltage at the presence of nonlinearities and unpredictable behaviors of the loads. As for a fast controller, a two-degree-of-freedom (DOF) controller is applied to the LC filter plant with the inverse dynamic model. The voltage command levels are selected considering the amount of power share with the grid. The effectiveness of the proposed control scheme is shown by experimental results.Keywords
This publication has 22 references indexed in Scilit:
- Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based MicrogridIEEE Transactions on Power Electronics, 2007
- Using Low Voltage MicroGrids for Service RestorationIEEE Transactions on Power Systems, 2007
- High-Quality Power Generation Through Distributed Control of a Power Park MicrogridIEEE Transactions on Industrial Electronics, 2006
- A modified direct power control strategy allowing the connection of three-phase inverter to the grid through LCL filters2005
- Novel Vector Control System Using Deadbeat-Controlled PWM Inverter With Output LC FilterIEEE Transactions on Industry Applications, 2004
- Fixed frequency sliding mode modulator for current mode PWM inverters2002
- UPS inverter design using discrete-time sliding-mode control schemeIEEE Transactions on Industrial Electronics, 2002
- A two-degrees-of-freedom current control scheme for deadtime compensationIEEE Transactions on Industrial Electronics, 2000
- Experimental study of a power conditioning system using sliding mode controlIEEE Transactions on Power Electronics, 1996
- Deadbeat control of PWM inverter with modified pulse patterns for uninterruptible power supplyIEEE Transactions on Industrial Electronics, 1988