Abstract
Introduction: Elliptical shape humeral head prostheses have been proposed to reflect a more anatomic shoulder replacement. Its effect on the rotational range of motion (ROM) compared to a standard spherical head is still not understood. The purpose was to investigate if there would be a difference in rotational ROM when comparing elliptical and spherical prosthetic heads in a dynamic shoulder model. The authors hypothesized that the use of elliptical heads would result in significantly more rotational ROM compared to the spherical head design.Materials and methods: Six fresh-frozen, cadaveric shoulders were evaluated using a dynamic shoulder model. After being tested in the native condition, each specimen underwent 6 conditions in the hemiarthroplasty state: (1) matched-fit spherical head, (2) oversized spherical head, (3) undersized spherical head, (4) matched-fit elliptical head, (5) oversized elliptical head, and (6) undersized elliptical head. Following conversion to total shoulder arthroplasty (TSA), the 6 prior conditions were rerun. Each condition was tested at 0°, 30° and 60° of glenohumeral abduction. Rotational ROM was quantified using 3-dimensional tracking, while dynamically applying alternating forces for internal and external rotation via the rotator cuff tendons.Results: Elliptical and spherical prosthetic heads showed no significant difference in the degree of the total, internal, and external rotational ROM for both the hemiarthroplasty and TSA state. Conversion from hemiarthroplasty to TSA resulted in less degree of total rotational ROM for both head designs in all abduction positions, without reaching statistical significance. There was a significant decrease in total, internal, and external rotational ROM for both elliptical and spherical heads in every replacement condition, when comparing 0° to 30° and 60° of abduction (P < 0.05, respectively).Conclusion: In a dynamic shoulder model, elliptical and spherical prosthetic head designs showed no significant difference in the degree of the total, internal, and external rotational ROM in both the hemiarthroplasty and TSA state.Level of evidence: Controlled laboratory studyKeywords
Funding Information
- Technische Universität München
This publication has 33 references indexed in Scilit:
- The effects of prosthetic humeral head shape on glenohumeral joint kinematics: a comparison of non-spherical and spherical prosthetic heads to the native humeral headJournal of Shoulder and Elbow Surgery, 2013
- Superior Capsule Reconstruction to Restore Superior Stability in Irreparable Rotator Cuff TearsThe American Journal of Sports Medicine, 2012
- Effect of deltoid tension and humeral version in reverse total shoulder arthroplasty: a biomechanical studyJournal of Shoulder and Elbow Surgery, 2012
- The effect of posterior capsular tightening on peak subacromial contact pressure during simulated active abduction in the scapular planeJournal of Shoulder and Elbow Surgery, 2009
- A Comparison of Pain, Strength, Range of Motion, and Functional Outcomes After Hemiarthroplasty and Total Shoulder Arthroplasty in Patients with Osteoarthritis of the ShoulderJournal of Bone and Joint Surgery, 2005
- Kinematics of the glenohumeral joint: Influences of muscle forces, ligamentous constraints, and articular geometryJournal of Orthopaedic Research, 1996
- Glenohumeral StabilityClinical Orthopaedics and Related Research, 1996
- A new dynamic testing apparatus to study glenohumeral joint motionJournal of Biomechanics, 1995
- A dynamic shoulder model: Reliability testing and muscle force studyJournal of Biomechanics, 1995
- Inertia and muscle contraction parameters for musculoskeletal modelling of the shoulder mechanismJournal of Biomechanics, 1991