G-stack modulated probe intensities on expression arrays - sequence corrections and signal calibration
Open Access
- 27 April 2010
- journal article
- research article
- Published by Springer Nature in BMC Bioinformatics
- Vol. 11 (1) , 1-24
Abstract
The brightness of the probe spots on expression microarrays intends to measure the abundance of specific mRNA targets. Probes with runs of at least three guanines (G) in their sequence show abnormal high intensities which reflect rather probe effects than target concentrations. This G-bias requires correction prior to downstream expression analysis. Longer runs of three or more consecutive G along the probe sequence and in particular triple degenerated G at its solution end ((GGG)1-effect) are associated with exceptionally large probe intensities on GeneChip expression arrays. This intensity bias is related to non-specific hybridization and affects both perfect match and mismatch probes. The (GGG)1-effect tends to increase gradually for microarrays of later GeneChip generations. It was found for DNA/RNA as well as for DNA/DNA probe/target-hybridization chemistries. Amplification of sample RNA using T7-primers is associated with strong positive amplitudes of the G-bias whereas alternative amplification protocols using random primers give rise to much smaller and partly even negative amplitudes. We applied positional dependent sensitivity models to analyze the specifics of probe intensities in the context of all possible short sequence motifs of one to four adjacent nucleotides along the 25meric probe sequence. Most of the longer motifs are adequately described using a nearest-neighbor (NN) model. In contrast, runs of degenerated guanines require explicit consideration of next nearest neighbors (GGG terms). Preprocessing methods such as vsn, RMA, dChip, MAS5 and gcRMA only insufficiently remove the G-bias from data. Positional and motif dependent sensitivity models accounts for sequence effects of oligonucleotide probe intensities. We propose a positional dependent NN+GGG hybrid model to correct the intensity bias associated with probes containing poly-G motifs. It is implemented as a single-chip based calibration algorithm for GeneChips which can be applied in a pre-correction step prior to standard preprocessing.Keywords
This publication has 54 references indexed in Scilit:
- Thermodynamic scaling behavior in genechipsBMC Bioinformatics, 2009
- An improved physico-chemical model of hybridization on high-density oligonucleotide microarraysBioinformatics, 2008
- Identification and analysis of functional elements in 1% of the human genome by the ENCODE pilot projectNature, 2007
- Explaining differences in saturation levels for Affymetrix GeneChip® arraysNucleic Acids Research, 2007
- Improving comparability between microarray probe signals by thermodynamic intensity correctionNucleic Acids Research, 2007
- Free energy of DNA duplex formation on short oligonucleotide microarraysNucleic Acids Research, 2006
- Assessing the performance of different high-density tiling microarray strategies for mapping transcribed regions of the human genomeGenome Research, 2006
- Non-linear analysis of GeneChip arraysNucleic Acids Research, 2006
- Model-based analysis of tiling-arrays for ChIP-chipProceedings of the National Academy of Sciences, 2006
- Relationship between gene expression and observed intensities in DNA microarrays--a modeling studyNucleic Acids Research, 2006