Reduction of resonant RF heating in intravascular catheters using coaxial chokes
Authors:
Open Access
- 3 April 2000
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 43 (4) , 615-619
Abstract
The incorporation of RF coils into the tips of intravascular devices has been shown to enable the localization of catheters and guidewires under MR guidance. Furthermore, such coils can be used for endoluminal imaging. The long cable required to connect the coil with the scanner input inadvertently acts as a dipole antenna which picks up RF energy from the body coil during transmit. Currents are induced on the cable which can lead to localized heating of surrounding tissue. Cables of various lengths were measured to determine if a resonance in the heating as a function of cable length could be found. Coaxial chokes with a length of λ/4 were added to coaxial cables to reduce the amplitude of the currents induced on the cable shield. A 0.7‐mm diameter triaxial cable, small enough to fit into a standard intravascular device, was developed and measured both with and without a coaxial choke. It is demonstrated that resonant heating does occur and that it can be significantly reduced by avoiding a resonant length of cable and by including coaxial chokes on the cable. Magn Reson Med 43:615–619, 2000.Keywords
This publication has 16 references indexed in Scilit:
- MR-guided percutaneous angioplasty: Assessment of tracking safety, catheter handling and functionalityCardioVascular and Interventional Radiology, 1998
- Active MR visualization of a vascular guidewire in vivoJournal of Magnetic Resonance Imaging, 1998
- Intravascular MR imaging of atherosclerotic plaque: ex vivo analysis of human femoral arteries with histologic correlation.Radiology, 1997
- Intravascular magnetic resonance imaging using a loopless catheter antennaMagnetic Resonance in Medicine, 1997
- High resolution intravascular MRI and MRS by using a catheter receiver coilMagnetic Resonance in Medicine, 1996
- Towards active guidewire visualization in interventional magnetic resonance imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 1996
- Radiofrequency ground heating for soil remediation: Science and engineeringEnvironmental Progress, 1994
- A theoretical model for input impedance of interstitial microwave antennas with chokeInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1994
- Real‐time position monitoring of invasive devices using magnetic resonanceMagnetic Resonance in Medicine, 1993
- A dipole antenna for interstitial microwave hyperthermiaIEEE Transactions on Microwave Theory and Techniques, 1991