The contribution of rate adaptive pacing with single or dual sensors to health-related quality of life
Open Access
- 9 March 2007
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 9 (4) , 233-238
Abstract
Aims The characteristics of sensors to perform rate adaptive pacing are well established but whether their contribution improves health-related quality of life (QoL) remains disputable. To compare the effects on QoL with an integrated dual sensor [minute ventilation (MV) and acceleration, TT sensor] with a single MV sensor, and with no rate adaptive pacing. Methods and results This Dutch multi centre, prospective, single- (patient) blind study was performed in patients after first pacemaker (PM) implant for sick sinus syndrome or AV block. After a 3-month ‘sensor off’-period following DDD PM implantation, where the latter 2 months permitted the MV sensor to learn the intrinsic rhythm, a 2-month period of DDDR with TT sensor or 2 months of DDDR with MV sensor, subsequently the two modes were crossed over. Quality of life was determined with Aquarel, the disease‐specific instrument for PM patients. Heart rate, percentages of sensor driven and intrinsic rhythm were retrieved from PM memories. Sixty-four patients completed the 7-month study. In sick sinus patients, percentages of sensor-driven pacing occurred significantly more frequently than in AV block patients After implant QoL improved significantly: before 71.3 and after 83.5% (P < 0.001) measured with Aquarel and in 3 of 9 SF-36 scales, but no significant additive QoL benefit with dual or MV sensor pacing was observed. Pacing diagnosis, percentages of rate adaptive pacing, and heart rate influencing medication did not influence this result. Conclusion Pacemaker implantation strongly improves QoL, but neither single- nor dual- sensor-driven pacing offered additional improvement in QoL during the initial 8 months after the first PM implant.Keywords
This publication has 27 references indexed in Scilit:
- Effect of pacing mode on health-related quality of life in the Canadian Trial of Physiologic PacingAmerican Heart Journal, 2003
- Ventricular Pacing or Dual-Chamber Pacing for Sinus-Node DysfunctionNew England Journal of Medicine, 2002
- Evaluation of the quality of rate adaptation algorithms for cardiac pacingEP Europace, 2001
- Current status of dual-sensor pacemaker systems for correction of chronotropic incompetenceThe American Journal of Cardiology, 2000
- Effects of Physiologic Pacing versus Ventricular Pacing on the Risk of Stroke and Death Due to Cardiovascular CausesNew England Journal of Medicine, 2000
- Evaluation of a Dual Sensor Rate Responsive Pacing System Based on a New ConceptPacing and Clinical Electrophysiology, 1998
- Quality of Life and Clinical Outcomes in Elderly Patients Treated with Ventricular Pacing as Compared with Dual-Chamber PacingNew England Journal of Medicine, 1998
- Cardiac Output Is a Sensitive Indicator of Difference in Exercise Performance Between Single and Dual Sensor PacemakersPacing and Clinical Electrophysiology, 1998
- Quality-of-Life in Patients Treated with Atrioventricular Synchronous Pacing Compared to Rate Modulated Ventricular Pacing: A Long-Term, Double-Blind, Crossover StudyPacing and Clinical Electrophysiology, 1992
- A New Rate‐Modulated Pacemaker System Optimized by Combination of Two SensorsPacing and Clinical Electrophysiology, 1988