Optimizing peptide nucleic acid probes for hybridization-based detection and identification of bacterial pathogens
- 10 January 2019
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (5) , 1565-1574
Abstract
Point-of-care (POC) diagnostics for infectious diseases have the potential to improve patient care and antibiotic stewardship. Nucleic acid hybridization is at the core of many amplification-free molecular diagnostics and detection probe configuration is key to diagnostic performance. Modified nucleic acids such as peptide nucleic acid (PNA) offer advantages compared to conventional DNA probes allowing for faster hybridization, better stability and minimal sample preparation for direct detection of pathogens. Probes with tethered fluorophore and quencher allow for solution-based assays and eliminate the need for washing steps thereby facilitating integration into microfluidic devices. Here, we compared the sensitivity and specificity of double stranded PNA probes (dsPNA) and PNA molecular beacons targeting E. coli and P. aeruginosa for direct detection of bacterial pathogens. In bulk fluid assays, the dsPNAs had an overall higher fluorescent signal and better sensitivity and specificity than the PNA beacons for pathogen detection. We further designed and tested an expanded panel of dsPNA probes for detection of a wide variety of pathogenic bacteria including probes for universal detection of eubacteria, Enterobacteriaceae family, and P. mirablis. To confirm that the advantage translated to other assay types we compared the PNA beacon and dsPNA in a prototype droplet microfluidic device. Beyond the bulk fluid assay and droplet devices, use of dsPNA probes may be advantageous in a wide variety of assays that employ homogenous nucleic acid hybridization.Keywords
Funding Information
- National Institutes of Health (R01 1AI117032, R01, 1AI117032)
This publication has 56 references indexed in Scilit:
- Multicenter Evaluation of the Staphylococcus QuickFISH Method for Simultaneous Identification of Staphylococcus aureus and Coagulase-Negative Staphylococci Directly from Blood Culture Bottles in Less than 30 MinutesJournal of Clinical Microbiology, 2012
- Clinical Validation of Integrated Nucleic Acid and Protein Detection on an Electrochemical Biosensor Array for Urinary Tract Infection DiagnosisPLOS ONE, 2011
- Biosensor diagnosis of urinary tract infections: a path to better treatment?Trends in Pharmacological Sciences, 2011
- Rapid Detection of Urinary Tract Infections Using Isotachophoresis and Molecular BeaconsAnalytical Chemistry, 2011
- A Biosensor Platform for Rapid Antimicrobial Susceptibility Testing Directly From Clinical SamplesJournal of Urology, 2011
- Visualizing the dynamics of viral replication in living cells via Tat peptide delivery of nuclease-resistant molecular beaconsProceedings of the National Academy of Sciences, 2008
- Then and now: use of 16S rDNA gene sequencing for bacterial identification and discovery of novel bacteria in clinical microbiology laboratoriesClinical Microbiology and Infection, 2008
- Avoiding false-positive signals with nuclease-vulnerable molecular beacons in single living cellsNucleic Acids Research, 2007
- Molecular Beacons: Probes that Fluoresce upon HybridizationNature Biotechnology, 1996
- PNA hybridizes to complementary oligonucleotides obeying the Watson–Crick hydrogen-bonding rulesNature, 1993