A Prospective Randomized Controlled Trial: Alternative Approach to EEG Application to Reduce Electrode-induced Skin Injury among Ambulatory EEG Patients
Authors:
- 2 January 2022
- journal article
- research article
- Published by Taylor & Francis in The Neurodiagnostic Journal
- Vol. 62 (1) , 37-51
Abstract
Ambulatory electroencephalography (AEEG) is a technique of continuous EEG recording of patients in their natural setting, outside the controlled environment of the hospital. Electrode-induced skin injury is a common complication of prolonged EEG monitoring. This randomized study aimed to investigate the performance of two methods of electrode application in reducing electrode-induced skin injury among patients undergoing 4-day AEEG monitoring. A randomized interventional study was conducted from November 2020 to May 2021 in the Neurosciences Ambulatory Care Unit at a metropolitan hospital in Sydney, Australia. We enrolled patients into two groups: i) Group 1 (standard protocol group) received Ten20 Conductive PasteTM with Tensive® adhesive gel as the primary approach to electrode application and ii) Group 2 (intervention group) received Ten20 Conductive PasteTM with Tensive® adhesive gel and hydrogel electrodes on hairless locations as the primary approach to electrode application. A total of 79 patients participated in this study. The group that received the addition of hydrogel electrodes (Group 2) performed better than the standard protocol group on electrode site inflammation for the frontal region, particularly FP1, FP2, F8, and the ground electrode sites. EEG quality and self-reports of patient comfort and mood did not differ significantly between the two groups. The addition of hydrogel electrodes using a Ten20 Conductive PasteTM with a Tensive® adhesive gel protocol results in reduced inflammation at frontal lobe and ground electrode sites.Keywords
This publication has 18 references indexed in Scilit:
- Alginate-based hydrogels as an alternative to electrolytic gels for rapid EEG monitoring and easy cleaning proceduresSensors and Actuators B: Chemical, 2017
- Diagnostic yield of ambulatory EEGs in the elderlyClinical Neurophysiology, 2017
- cEEG electrode-related pressure ulcers in acutely hospitalized patientsNeurology Clinical Practice, 2017
- American Clinical Neurophysiology Society Guideline 1: Minimum Technical Requirements for Performing Clinical ElectroencephalographyJournal Of Clinical Neurophysiology, 2016
- Skin Irritation during Video-EEG MonitoringThe Neurodiagnostic Journal, 2016
- The role of outpatient ambulatory electroencephalography in the diagnosis and management of adults with epilepsy or nonepileptic attack disorder: A systematic literature reviewEpilepsy & Behavior, 2015
- Preventing Skin Breakdown in EEG Patients: Best Practice TechniquesJournal of Pediatric Nursing, 2014
- The utility of ambulatory electroencephalography in routine clinical practice: A critical reviewEpilepsy Research, 2013
- The utility of prolonged outpatient ambulatory EEGSeizure: European Journal of Epilepsy, 2012