Integrated Nanosecond Pulse Irreversible Electroporation (INSPIRE): Impact of Exposed Electrode Length on Ablation Geometry in an In Vivo Liver Model
Authors:
- Jordan A. FongJFJordan A. Fong
- Logan ReegLRLogan Reeg
- Jewels DarrowJDJewels Darrow
- Robert H. WilliamsonRWRobert H. Williamson
- Anna RiordanARAnna Riordan
- Alexia K. CashACAlexia K. Cash
- Max BeecroftMBMax Beecroft
- Callie A. FogleCFCallie A. Fogle
- Kyle G. MathewsKMKyle G. Mathews
- Nathan C. NelsonNNNathan C. Nelson
- Alina C. IugaAIAlina C. Iuga
- David A. GerberDGDavid A. Gerber
Open Access
Abstract
Objectives: There is a critical need for effective focal therapies for patients with inoperable or anatomically complex tumors where conventional ablation techniques pose high risk or are ineffective. Integrated Nanosecond Pulsed Irreversible Electroporation (INSPIRE) is a novel non-thermal ablation modality which uses real time temperature feedback during pulse delivery to safely treat tumors near critical structures. This study evaluated the impact of exposed electrode length on ablation zone size, reproducibility, and cardiac safety in a large animal model. Methods: INSPIRE treatments were performed in an in vivo healthy porcine liver model. All treatments administered 6000 V 1000 ns pulses with a 45 °C temperature set point. Treatments were administered percutaneously via an electrode and grounding pad approach using an internally cooled electrode applicator. The exposed electrode region at the distal end of the applicator was set to either 0.5, 1.0, 1.5, or 2.0 cm. Ablation zones were assessed via ultrasound, contrast-enhanced CT, and gross pathology one week post-treatment. Cardiac safety was evaluated by measuring pre- and post-treatment serum Troponin levels. Results: All treatments were completed without adverse events. Troponin levels remained stable (pre: 0.249 ng/mL; post: 0.224 ng/mL), indicating no measurable cardiac injury. The 1.5 cm exposure length produced the largest and most consistent ablation volumes, with a mean volume of 12.8 ± 2.6 cm3 and average dimensions of 3.7 × 2.7 cm in under 6 min. Increasing exposure length beyond 1.5 cm introduced greater variability and reduced treatment volumes. Conclusions: INSPIRE enables safe, large-volume, single-applicator ablation without a need for electrical pulse synchronization with R wave in cardiac rhythm. The 1.5 cm exposure length offers optimal balance between energy delivery and treatment consistency. These findings support further clinical investigation of INSPIRE for non-thermal ablation of inoperable tumors.Keywords
Funding Information
- National Cancer Institute of the National Institutes of Health (R01CA276232, R01CA272550, R41CA275587)
- NCSU Chancellor’s Innovation Fund (R01CA276232, R01CA272550, R41CA275587)
This publication has 67 references indexed in Scilit:
- Safety and early efficacy of irreversible electroporation for hepatic tumors in proximity to vital structuresJournal of Surgical Oncology, 2012
- A brief overview of electroporation pulse strength–duration space: A region where additional intracellular effects are expectedBioelectrochemistry, 2012
- Ablation of Perivascular Hepatic Malignant Tumors with Irreversible ElectroporationJournal of the American College of Surgeons, 2012
- High-frequency irreversible electroporation (H-FIRE) for non-thermal ablation without muscle contractionBioMedical Engineering OnLine, 2011
- Synergistic effects of local temperature enhancements on cellular responses in the context of high-intensity, ultrashort electric pulsesMedical & Biological Engineering & Computing, 2011
- Irreversible Electroporation of Renal Cell Carcinoma: A First-in-Man Phase I Clinical StudyCardioVascular and Interventional Radiology, 2010
- Imaging Guided Percutaneous Irreversible Electroporation: Ultrasound and Immunohistological CorrelationTechnology in Cancer Research & Treatment, 2007
- In Vivo Results of a New Focal Tissue Ablation Technique: Irreversible ElectroporationIEEE Transactions on Biomedical Engineering, 2006
- Tissue Ablation with Irreversible ElectroporationAnnals of Biomedical Engineering, 2005
- Comparison of Cardiac Troponin I, Creatine Kinase-MB, and Myoglobin for Detection of Acute Ischemic Myocardial Injury in a Swine ModelAmerican Journal of Clinical Pathology, 1998